Back to the drug test guide

Methamphetamine Test Evidence

Has Caused a False Positive

Phenylephrine

Source Curtin and Cawley, Pharmacotherapy 2012

What It Found

  • An ICU patient screened positive after intravenous phenylephrine, and a follow-up investigation implicated the drug or its metabolites.

Keep in Mind

  • The patient received intravenous therapy.

Test Studied

  • Clinical urine methamphetamine screen

Source FDA 510(k) K060896. Varian OnTrak TesTcup II and OnSite CupKit. Decision summary…, 2006

What It Found

  • In a separate FDA submission, l-phenylephrine at 50 micrograms/mL triggered the evaluated strip in fortified urine.

Test Studied

  • Varian OnSite CupKit methamphetamine strip, 300 ng/mL cutoff

Both sources Curtin and Cawley, Pharmacotherapy 2012 FDA 510(k) K060896. Varian OnTrak TesTcup II and OnSite CupKit. Decision summary…, 2006

Keep in Mind

  • These sources do not establish the effect of common oral or nasal formulations at recommended doses.

Ranitidine

Source Ayala-Lopez et al., J Anal Toxicol 2022

What It Found

  • Preliminary clinical associations prompted an Alere cup experiment that reproduced a positive with 50 micrograms/mL of added ranitidine.

Test Studied

  • Alere Integrated E-Z Split Key Cup II

Source FDA 510(k) K060896. Varian OnTrak TesTcup II and OnSite CupKit. Decision summary…, 2006

What It Found

  • A separate FDA submission documented a positive at 25 micrograms/mL on a different methamphetamine strip.

Test Studied

  • Varian OnSite CupKit methamphetamine channels

Both sources Ayala-Lopez et al., J Anal Toxicol 2022 FDA 510(k) K060896. Varian OnTrak TesTcup II and OnSite CupKit. Decision summary…, 2006

Keep in Mind

  • The concentrations are specific to the cups and cutoffs.
  • A product name is useful only after checking the active ingredient.

Ephedra

Source Levisky et al., J Anal Toxicol 2003

What It Found

  • A published report describes a false-positive methamphetamine radioimmunoassay after an ephedra-derived herbal product.

Keep in Mind

  • The indexed record does not specify which constituent triggered the result.
  • Product formulations vary.

Test Studied

  • Methamphetamine radioimmunoassay

Ephedrine

Source D'Nicuola et al., J Anal Toxicol 1992

What It Found

  • In a multi-assay experiment, urine fortified with the l-ephedrine isomer reacted on some methamphetamine assays at 1,000 mg/L.

Keep in Mind

  • No spiked compounds in that comparison reacted at 100 mg/L.
  • The laboratory concentration is not a prediction for a person taking ephedrine.

Test Studied

  • Roche and DPC methamphetamine radioimmunoassays

Source Aoki and Kuroiwa, Forensic Sci Int 1985

What It Found

  • The assay reacted to added Ephedrine in the analogue challenge.

Keep in Mind

  • The abstract reports differing degrees of reaction without a medication-specific threshold or observed patient false positive.

Test Studied

  • Experimental latex agglutination urine methamphetamine assay with a 0.4 µg/mL methamphetamine sensitivity

Source Apollonio et al., J Anal Toxicol 2007

What It Found

  • In a comparison with 50 ng/mL target standards, the assay's relative response to Ephedrine was 9%.

Keep in Mind

  • The authors evaluated urine separately as a specimen matrix.
  • The standard comparison does not show an individual post-dose positive.

Test Studied

  • Bio-Quant Direct ELISA for methamphetamine

Meta-chlorophenylpiperazine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Meta-chlorophenylpiperazine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 1.5 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Methoxyphenamine

Source Aoki and Kuroiwa, Forensic Sci Int 1985

What It Found

  • The assay reacted to added Methoxyphenamine in the analogue challenge.

Keep in Mind

  • The abstract reports differing degrees of reaction without a medication-specific threshold or observed patient false positive.

Test Studied

  • Experimental latex agglutination urine methamphetamine assay with a 0.4 µg/mL methamphetamine sensitivity

Methylephedrine

Source Aoki and Kuroiwa, Forensic Sci Int 1985

What It Found

  • The assay reacted to added Methylephedrine in the analogue challenge.

Keep in Mind

  • The abstract reports differing degrees of reaction without a medication-specific threshold or observed patient false positive.

Test Studied

  • Experimental latex agglutination urine methamphetamine assay with a 0.4 µg/mL methamphetamine sensitivity

Pseudoephedrine

Source D'Nicuola et al., J Anal Toxicol 1992

What It Found

  • Drug-free urine containing high concentrations of d-pseudoephedrine reacted on certain methamphetamine-specific assays.

Keep in Mind

  • Older reagents had differing responses.
  • Evidence from concentrated spiked urine does not predict a positive result at usual doses.

Test Studied

  • Roche and DPC methamphetamine radioimmunoassays

Source Apollonio et al., J Anal Toxicol 2007

What It Found

  • In a comparison with 50 ng/mL target standards, the assay's relative response to Pseudoephedrine was 19%.

Keep in Mind

  • The authors evaluated urine separately as a specimen matrix.
  • The standard comparison does not show an individual post-dose positive.

Test Studied

  • Bio-Quant Direct ELISA for methamphetamine

Trimethobenzamide

Source Interference of Selected Clinical Medicines on DRI and TDx Immunoassays of Morphine and…, 1999

What It Found

  • In a drug-free urine experiment, adding 500 micrograms/mL of trimethobenzamide produced an apparent methamphetamine concentration above 4,000 ng/mL.

Keep in Mind

  • The study used laboratory concentrations.
  • Its design does not establish the interference rate among patients.

Test Studied

  • DRI amphetamines reagent calibrated for methamphetamine, 500 ng/mL cutoff

Depends on the Brand of Test

Dextroamphetamine

Source FDA decision summary K122961. Wondfo Methamphetamine Urine Test (MET 500) and Amphetamine…, 2013

What It Found

  • Added dextroamphetamine produced a positive methamphetamine-specific Wondfo result at 50,000 ng/mL.

Test Studied

  • Wondfo MET500

Source FDA decision summary K152590. Coretests ACCU NEWS Drug Screening Test Card and Urine Cup, 2016

What It Found

  • ACCU NEWS remained below cutoff at 100,000 ng/mL.

Test Studied

  • ACCU NEWS MET1000 urine tests

2 sources FDA decision summary K122961. Wondfo Methamphetamine Urine Test (MET 500) and Amphetamine…, 2013 FDA decision summary K152590. Coretests ACCU NEWS Drug Screening Test Card and Urine Cup, 2016

Keep in Mind

  • These tests used the active drug in spiked urine.
  • They do not show that a prescribed dose regularly triggers a methamphetamine-specific screen.

2 sources Helander et al., Drug Test Anal 2025 Contella et al., J Mass Spectrom Adv Clin Lab 2025

Keep in Mind

  • A separate finding of a very small amount of actual methamphetamine on sensitive mass spectrometry has been described in patients taking d-amphetamine products.

Test Studied

  • Separate studies examined urinary amphetamines by targeted mass spectrometry

Lisdexamfetamine

2 sources FDA decision summary K122961. Wondfo Methamphetamine Urine Test (MET 500) and Amphetamine…, 2013 FDA decision summary K152590. Coretests ACCU NEWS Drug Screening Test Card and Urine Cup, 2016

What It Found

  • The body converts lisdexamfetamine to dextroamphetamine.

Keep in Mind

  • These tests used the active drug in spiked urine.
  • They do not show that a prescribed dose regularly triggers a methamphetamine-specific screen.

Source FDA decision summary K122961. Wondfo Methamphetamine Urine Test (MET 500) and Amphetamine…, 2013

What It Found

  • Added dextroamphetamine triggered the Wondfo methamphetamine strip at 50,000 ng/mL.

Test Studied

  • Wondfo MET500

Source FDA decision summary K152590. Coretests ACCU NEWS Drug Screening Test Card and Urine Cup, 2016

What It Found

  • ACCU NEWS remained below cutoff at 100,000 ng/mL.

Test Studied

  • ACCU NEWS MET1000 urine tests

2 sources Helander et al., Drug Test Anal 2025 Contella et al., J Mass Spectrom Adv Clin Lab 2025

Keep in Mind

  • A separate finding of a very small amount of actual methamphetamine on sensitive mass spectrometry has been described in patients taking d-amphetamine products.

Test Studied

  • Separate studies examined urinary amphetamines by targeted mass spectrometry

Phentermine

Source Aoki and Kuroiwa, Forensic Sci Int 1985

What It Found

  • The assay reacted to added Phentermine in the analogue challenge.

Keep in Mind

  • The abstract reports differing degrees of reaction without a medication-specific threshold or observed patient false positive.

Test Studied

  • Experimental latex agglutination urine methamphetamine assay with a 0.4 µg/mL methamphetamine sensitivity

Source FDA 510(k) K153693. Immunalysis Methamphetamine Urine Enzyme Immunoassay, 2016

What It Found

  • Phentermine remained negative on the dedicated Immunalysis methamphetamine assay even at 1,000,000 ng/mL in the laboratory.

Keep in Mind

  • Some broad amphetamines assays detect phentermine.
  • A positive on a class screen cannot identify the substance as methamphetamine.
  • The result on this dedicated assay is device-specific.

Test Studied

  • Immunalysis Methamphetamine Urine Enzyme Immunoassay

A Related Drug the Test Picks Up

3,4-Dimethylmethcathinone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 3,4-Dimethylmethcathinone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 60 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

3-Trifluoromethylphenylpiperazine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 3-TFMPP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 0.7 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-CAP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-CAP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 90 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-EEC

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-EEC challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 50 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-Fluoroamphetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-Fluoroamphetamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 50 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-Fluoromethamphetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-Fluoromethamphetamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 1.5 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-MEC

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-MEC challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 50 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-MePPP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-MePPP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 80 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-Methylamphetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-Methylamphetamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 15 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-Methylthioamphetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-Methylthioamphetamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 20 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-MPBP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-MPBP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 55 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-APB

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-APB challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 10 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-APDB

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-APDB challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 25 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-APDI

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-APDI challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 4 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-IT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-IT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 12.5 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

6-APB

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 6-APB challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 8 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Alpha-PBP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Alpha-PBP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 90 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Benzylpiperazine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Benzylpiperazine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 30 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Buphedrone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Buphedrone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 11 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Butylone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Butylone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 16 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Dimethylone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Dimethylone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 30 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Dimethyltryptamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Dimethyltryptamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 30 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Ethcathinone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Ethcathinone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 65 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Ethylone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Ethylone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 55 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Eutylone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Eutylone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 60 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

MBDB

Source Apollonio et al., J Anal Toxicol 2007

What It Found

  • In a comparison with 50 ng/mL target standards, the assay's relative response to MBDB was 8%.

Keep in Mind

  • The authors evaluated urine separately as a specimen matrix.
  • The standard comparison does not show an individual post-dose positive.

Test Studied

  • Bio-Quant Direct ELISA for methamphetamine

MDEA

Source Apollonio et al., J Anal Toxicol 2007

What It Found

  • In a comparison with 50 ng/mL target standards, the assay's relative response to MDEA was 18%.

Keep in Mind

  • The authors evaluated urine separately as a specimen matrix.
  • The standard comparison does not show an individual post-dose positive.

Test Studied

  • Bio-Quant Direct ELISA for methamphetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the MDEA challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 13 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

MDMA

Source Apollonio et al., J Anal Toxicol 2007

What It Found

  • In a comparison with 50 ng/mL target standards, the assay's relative response to MDMA was 73%.

Keep in Mind

  • The authors evaluated urine separately as a specimen matrix.
  • The standard comparison does not show an individual post-dose positive.

Test Studied

  • Bio-Quant Direct ELISA for methamphetamine

MDPBP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the MDPBP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 80 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Mephedrone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Mephedrone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 25 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Methcathinone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Methcathinone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 35 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Methedrone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Methedrone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 50 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Methiopropamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Methiopropamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 1 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Methylone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Methylone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 25 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

N,N-Dimethylcathinone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the N,N-Dimethylcathinone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 50 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Pentedrone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Pentedrone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 40 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

PMA

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the PMA challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 35 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

PMMA

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the PMMA challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL gave a positive result at 1 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

The Test Is Made to Find It

Amphetamine/dextroamphetamine mixed salts

Source Contella et al., J Mass Spectrom Adv Clin Lab 2025

What It Found

  • In a pharmaceutical impurity investigation, LC-MS/MS measured trace methamphetamine in an Adderall XR preparation and in some specimens from people prescribed amphetamine.

Source Helander et al., Drug Test Anal 2025

What It Found

  • Separate researchers reported evidence consistent with a minor metabolic contribution.

Source Oh et al., J Pharm Biomed Anal 1992

What It Found

  • The 1991 prototype showed less than 7% relative antibody response to amphetamine.

Test Studied

  • Prototype biotin–avidin nephelometric urine assay, cutoff 700 ng/mL

Source Korte et al., J Anal Toxicol 1997

What It Found

  • RapiTest MET also reacted with amphetamine.

Test Studied

  • RapiTest One Step Methamphetamine Test

2 sources Contella et al., J Mass Spectrom Adv Clin Lab 2025 Helander et al., Drug Test Anal 2025

Keep in Mind

  • These were low-level definitive findings, outside the usual concept of a false-positive screen.
  • Neither study supplies a universal ratio or resolves the cause in an individual.

Tests Studied

  • Highly sensitive LC-MS/MS
  • Trace methamphetamine interpretation

2 sources Oh et al., J Pharm Biomed Anal 1992 Korte et al., J Anal Toxicol 1997

Keep in Mind

  • The investigators did not establish a drug-only urine concentration producing a positive call in the abstract.
  • The authors did not give an exposure-specific risk for prescription amphetamine formulations.

Benzphetamine

Source Cody and Valtier, J Anal Toxicol 1998

What It Found

  • Benzphetamine can produce d-methamphetamine and d-amphetamine.
  • The amounts differed among people in a controlled study.

Keep in Mind

  • An isomer result alone cannot distinguish all possible sources of d-methamphetamine.
  • Medication history matters.

Test Studied

  • Urine GC-MS with enantiomer analysis

Source Choi et al., J Immunoassay 1995

What It Found

  • The assay intentionally recognized the parent benzphetamine, with a reported detection limit of 0.05 ppm.

Keep in Mind

  • This prototype was designed for both drugs.
  • Parent recognition is separate from the formation of methamphetamine in the body.

Test Studied

  • Experimental dual-target methamphetamine/benzphetamine urine polarization fluoroimmunoassay

Levomethamphetamine

Source Smith et al., J Anal Toxicol 2014

What It Found

  • A controlled study of a nasal inhaler formulation containing levmetamfetamine detected real l-methamphetamine in urine and no d-methamphetamine.

Keep in Mind

  • Only inhalers containing this ingredient are relevant.
  • Product names and formulations can vary.

Test Studied

  • Enantiomer-specific GC-MS following controlled inhaler use

Source Hamilton et al., J Anal Toxicol 2014

What It Found

  • At high l-methamphetamine concentrations, the integration software could misassign a peak as d-methamphetamine on this GC-MS method.

Keep in Mind

  • This is a stereoisomer-assignment artifact in a specific confirmatory method.

Test Studied

  • Chiral GC-EI-MS with R-(−)-MTPA derivatization

Famprofazone

Source Cody, Forensic Sci Int 1996

What It Found

  • Famprofazone metabolism yielded d- and l-methamphetamine in urine.

Keep in Mind

  • This is a real metabolite finding from a small study.
  • Product availability depends on country.

Test Studied

  • Urine enantiomer analysis after oral administration

Methamphetamine

Source Kim et al., Ther Drug Monit 2004

What It Found

  • A prescription containing methamphetamine supplies the actual test target.
  • Controlled administration produced urinary methamphetamine.

Keep in Mind

  • A positive test does not by itself identify the reason for the exposure.

Test Studied

  • GC-MS after controlled oral methamphetamine

Selegiline

Both sources Shin, Drug Metab Dispos 1997 Ramseier et al., Electrophoresis 1999

What It Found

  • Selegiline produces l-methamphetamine as a genuine metabolite.
  • A test that does not distinguish isomers may report methamphetamine.

Keep in Mind

  • The l-isomer is relevant to interpreting the source of the finding.

Source Ramseier et al., Electrophoresis 1999

What It Found

  • The authors confirmed the R isomer of methamphetamine in urine from a patient taking selegiline.

Keep in Mind

  • The finding concerns actual metabolite identity.

Test Studied

  • Urine chiral capillary electrophoresis

Source Shin, Drug Metab Dispos 1997

Test Studied

  • Isomer-specific urine analysis after human selegiline administration

Tested: No False Positive Found

2,5-Dimethoxyamphetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2,5-Dimethoxyamphetamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2,5-Dimethoxyamphetamine did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

2-Aminoindane

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2-Aminoindane challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

2-DPMP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2-DPMP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

25B-NBOMe

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 25B-NBOMe challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

25C-NBOMe

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 25C-NBOMe challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

25I-NBOMe

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 25I-NBOMe challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

2C-B

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-B challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

2C-C

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-C challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

2C-E

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-E challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

2C-I

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-I challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

2C-N

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2C-N did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

2C-T

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-T challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2C-T did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

2C-T-13

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2C-T-13 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

2C-T-17

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2C-T-17 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

2C-T-2

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-T-2 challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2C-T-2 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

2C-T-4

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-T-4 challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

2C-T-5

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2C-T-5 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

2C-T-7

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 2C-T-7 challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 2C-T-7 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

3,4,5-Trimethoxyamphetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 3,4,5-Trimethoxyamphetamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • 3,4,5-Trimethoxyamphetamine did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

4-HO-DET

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-HO-DET challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-Methoxyphencyclidine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-Methoxyphencyclidine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

4-TFMPP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 4-TFMPP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-IAI

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-IAI challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-MeO-AMT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-MeO-AMT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-MeO-DALT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-MeO-DALT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-MeO-DiPT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-MeO-DiPT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-MeO-DMT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-MeO-DMT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

5-MeO-MiPT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the 5-MeO-MiPT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Acetaminophen

Source Lin et al., J Anal Toxicol 2013

What It Found

  • The authors observed no interference from Acetaminophen at 1,000 ng/mL when it was added to drug-free urine for the cup comparison.

Keep in Mind

  • This is a single challenge level.
  • It cannot rule out interference at a higher concentration or with a different device.

Test Studied

  • NexScreen and DrugCheck Waive RT cups, as applicable to their respective panels

ALEPH

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • ALEPH did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

ALEPH-13

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • ALEPH-13 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

ALEPH-17

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • ALEPH-17 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

ALEPH-2

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • ALEPH-2 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

ALEPH-5

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • ALEPH-5 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

ALEPH-7

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • ALEPH-7 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Alpha-methyltryptamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Alpha-methyltryptamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Alpha-PPP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Alpha-PPP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Alpha-PVP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Alpha-PVP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Alpha-PVT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Alpha-PVT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Benocyclidine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Benocyclidine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Benzedrone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Benzedrone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

BOB

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • BOB did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

BOD

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • BOD did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

BOH

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • BOH did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

BOHD

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • BOHD did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Bromo-DragonFLY

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Bromo-DragonFLY challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Bupropion

Source FDA 510(k) K253567. Healgen Accurate Urine Drug Screen Dip Card and Home Urine Drug Test…, 2025

What It Found

  • Bupropion added at 100 µg/mL did not change the methamphetamine result on this urine device.

Keep in Mind

  • Only parent bupropion was tested here.

Test Studied

  • Healgen Accurate dip-card methamphetamine channels, 500 or 1,000 ng/mL d-methamphetamine cutoffs

Source Reidy et al., Ther Drug Monit 2011

Keep in Mind

  • Its metabolites can interfere with some amphetamines-class immunoassays, which ask a different question.

Cathinone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Cathinone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

D2PM

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the D2PM challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Dextromethorphan

Source Lin et al., J Anal Toxicol 2013

What It Found

  • The authors observed no interference from Dextromethorphan at 1,000 ng/mL when it was added to drug-free urine for the cup comparison.

Keep in Mind

  • This is a single challenge level.
  • It cannot rule out interference at a higher concentration or with a different device.

Test Studied

  • NexScreen and DrugCheck Waive RT cups, as applicable to their respective panels

Dibenzylpiperazine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Dibenzylpiperazine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Diethylpropion

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Diethylpropion challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Dimethylamylamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Dimethylamylamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Diphenhydramine

Source Lin et al., J Anal Toxicol 2013

What It Found

  • The authors observed no interference from Diphenhydramine at 1,000 ng/mL when it was added to drug-free urine for the cup comparison.

Keep in Mind

  • This is a single challenge level.
  • It cannot rule out interference at a higher concentration or with a different device.

Test Studied

  • NexScreen and DrugCheck Waive RT cups, as applicable to their respective panels

Dipropyltryptamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Dipropyltryptamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

DiPT

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the DiPT challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

DOB

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the DOB challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

DOC

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the DOC challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • DOC did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

DOET

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the DOET challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • DOET did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

DOI

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the DOI challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • DOI did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Both sources Regester et al., J Anal Toxicol 2015 Nieddu et al., J Anal Toxicol 2016

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.
  • Different antibody formulations can give different results.

DOM

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the DOM challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

DON

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • DON did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

DOPR

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • DOPR did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

Escaline

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Escaline challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Flephedrone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Flephedrone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

MDAI

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the MDAI challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

MDBZ

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • MDBZ did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

MDCPM

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • MDCPM did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

MDIP

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • MDIP did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

MDPPP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the MDPPP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Meprobamate

Source Lin et al., J Anal Toxicol 2013

What It Found

  • The authors observed no interference from Meprobamate at 1,000 ng/mL when it was added to drug-free urine for the cup comparison.

Keep in Mind

  • This is a single challenge level.
  • It cannot rule out interference at a higher concentration or with a different device.

Test Studied

  • NexScreen and DrugCheck Waive RT cups, as applicable to their respective panels

Mescaline

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Mescaline challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Methoxetamine

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Methoxetamine challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Methylenedioxypyrovalerone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Methylenedioxypyrovalerone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

MOPPP

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the MOPPP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

MPHP (study designation)

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the MPHP challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

MT-45

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the MT-45 challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Naphyrone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Naphyrone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Pentylone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Pentylone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

Pyrovalerone

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the Pyrovalerone challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL

TMA-2

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • TMA-2 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

TMA-3

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • TMA-3 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

TMA-6

Source Nieddu et al., J Anal Toxicol 2016

What It Found

  • TMA-6 did not give a positive Neogen Methamphetamine/MDMA urine screen at tested concentrations up to 10,000 ng/mL.

Keep in Mind

  • Urine results were evaluated separately from blood and oral fluid.
  • Different antibody formulations can give different results.

Test Studied

  • Neogen Methamphetamine/MDMA urine ELISA

WIN 35,428

Source Regester et al., J Anal Toxicol 2015

What It Found

  • In the WIN 35,428 challenge, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL stayed negative at 100 µg/mL.

Keep in Mind

  • These were pure reference compounds added to drug-free human urine.
  • The concentrations do not predict a positive result after use in a patient.

Test Studied

  • Urine screening on Roche/Hitachi Modular P, Lin-Zhi Methamphetamine, calibrated at 250 ng/mL