Technescan HDP Technetium Tc 99m Oxidronate 3.15 mg Injection, Powder, Lyophilized, For Solution, 5 vials — NDC 69945-0091-20 package photo

Technescan HDP Technetium Tc 99m Oxidronate 3.15 mg Injection, Powder, Lyophilized, For Solution, 5 vials

by Curium US LLC · 5 VIAL in 1 CELLO PACK (69945-091-20) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL
NDC 69945-0091-20
🏷️ FDA NDC (as labeled) 69945-091-20 billing pads the product segment with a zero
This package
Contains5 vials Pack sizes2 compare ↓
Also comes in: 30 vials 69945-0091-40
Rx only Brand On market Non-controlled
🗂️ Data synced Jul 24, 2026 · sources: openFDA · FDA label (DailyMed) · FDA Orange & Purple Book · First Databank · CMS NADAC, ASP, Medicare & Medicaid · RxNorm
📋 All sources & update times →

🆔 Identity & classification

FDA NDC (as labeled) 69945-091-20
Product NDC 69945-091
11-digit billing NDC 69945009120
NCPDP billing unit EA — each (per item)
UNII H852YK87WP
Application # NDA018321
SPL Set ID 6fc2e41e-a1bf-4e0f-924a-88be0372d4af
DEA schedule Non-controlled
Marketing category NDA
Marketing status On market
FDA listing status Listed (active directory)
Marketing start 2015-10-13
Route INTRAVENOUS
Dosage form INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION
Substance OXIDRONATE DISODIUM
GCN Seq No 080157
GCN 46857
HICL code 024557
Ingredient (HICL) Kit For Tc-99M/Sod Oxidronate
HIC1 code Z
Therapeutic class — broad (HIC1) Body As A Whole
HIC2 code Z9
Therapeutic class — intermediate (HIC2) Unclassified Drugs
HIC3 code Z9D
Therapeutic class — specific (HIC3) Diagnostic Preparations,Miscellaneous
AHFS code 36:68.00.00
AHFS class Roentgenography And Other Imaging Agents
FDB label name TECHNESCAN HDP PREP KIT
FDB brand name Technescan Hdp
Legend status F — Federal legend — prescription drug or device
Why two NDCs? The FDA registers this code as 69945-091-20 — a 5-3-2 layout, and that's what's printed on the package and shown on DailyMed. For insurance claims, every NDC is standardized to a uniform 11-digit 5-4-2 format by adding a zero to the product segment → 69945-0091-20. Same drug, same package — only the format differs.
Where does this data come from?
Identifiers from the FDA openFDA NDC Directory and Structured Product Labeling; RxCUI from RxNorm (NLM); GPI from Medi-Span; GCN / HIC / AHFS / legend from First Databank.

🏭 Manufacturer & labeler

LabelerCurium US LLC
Application holderCURIUM US LLC
FDA applicationNDA018321 (NDA)
Labeler code69945
First marketedOct 2015
Product typeHuman Prescription Drug
Portfolio34 products on file
The labeler markets the product; the application holder owns the FDA approval. They’re often the same company but can differ (e.g. a repackager or an authorized generic). A mailing address / phone appears here when the manufacturer includes it in the product’s FDA label (not all do).
Where does this data come from?
Labeler, application holder and registered establishment from the FDA openFDA NDC Directory and Drugs@FDA; address/contact from the product’s FDA label.

🩺 Clinical

Label name TECHNESCAN HDP PREP KIT Ingredient Kit For Tc-99M/Sod Oxidronate
Where does this data come from?
Plain-language summary from MedlinePlus (U.S. National Library of Medicine); supplement & herbal interactions and nutrient depletion data from the Natural Medicines database; our full guide is HelloPharmacist editorial content.

🧪 Inactive Ingredients / Excipients

Inactive ingredients, also called excipients, are components of the drug product other than the active ingredient. They may include fillers, dyes, coatings, preservatives, flavors, or other formulation ingredients.

💡 Tap an ingredient (hover on desktop) to see what it is and why it’s used.

  • UNII VP36V95O3T
    Gentisic acid is a naturally occurring organic compound used in pharmaceuticals as a buffer and pH stabilizer. It helps maintain the correct acidity level in medicines to improve stability and ensure consistent performance.
  • UNII 451W47IQ8X
    Sodium chloride is common table salt. It's used in medicines as a buffer to maintain proper pH, as a filler to add bulk, or to adjust the osmotic balance in liquid formulations.
  • UNII 1BQV3749L5
    Stannous chloride is a tin-based chemical compound used as a reducing agent and antioxidant in pharmaceuticals. It helps prevent oxidation of active ingredients and stabilizes certain formulations, particularly in products requiring preservation of potency.

3 inactive ingredients listed in the exact product block matched to this NDC.

Where does this data come from?
Data sourced from official FDA Structured Product Labeling (SPL) via DailyMedingredient classCode="IACT" elements from the exact product block matched by this NDC. Label-section narrative from DailyMed / the openFDA label index is shown separately when available.

Inactive ingredient FAQ

Are inactive ingredients the same for every manufacturer?
No. Inactive ingredients can differ by manufacturer, dosage form, strength, and package / product version.
Why might an inactive ingredient be missing?
Some SPLs do not provide a complete structured inactive-ingredient list, and older or unusual labels may only include the information in narrative text.
Can inactive ingredients matter?
Yes. They can matter for allergies, intolerances, dyes, gluten / lactose concerns, preservatives, and formulation differences — but confirm with a pharmacist or the manufacturer when it’s clinically important.

💲 Pricing

A drug doesn't have one price. Each row is a different public payment system, and none is what you'd pay at the counter — that depends on your insurance. The ⓘ on each row explains what it measures.

Price systemPer mLPer package
Retail pharmacies payNADAC · weekly Not in the retail survey — common for institutional, discontinued, or low-volume packs.
Medicaid paysCMS SDUD · 12 mo No recent Medicaid claims on file for this NDC — rare and low-volume NDCs are suppressed in the public data.
Medicare drug plans payPart D · quarterly No Part D plan price is available for this NDC in our data.
ℹ️
No price is published for this exact package yet. CMS surveys NADAC per package size, so a different pack of the same drug often has one.
Try another pack size: 30 vials
Where does this data come from?
NADAC (National Average Drug Acquisition Cost) is the CMS weekly pharmacy-acquisition-cost survey — what pharmacies pay. ASP (Average Sales Price) is the CMS Medicare Part B drug-payment file, published quarterly. Medicaid pays is computed by us from CMS State Drug Utilization Data (total reimbursed ÷ units, trailing 12 months) — gross of rebates and inclusive of dispensing fees, so it reflects what Medicaid paid, not an acquisition cost. Medicare drug plans pay is the median negotiated point-of-sale unit cost across plans listing this NDC in the CMS quarterly Prescription Drug Plan pricing files, before rebates. The VA pays is the federal contract price (FSS, and the statutory Big 4 ceiling where listed) from the VA National Acquisition Center pharmaceutical price file. All are free public government data; each measures a different payer, so the figures are not directly comparable.

🔁 Therapeutic equivalents

ProductLabelerPackNADAC/unitTEStatusPrice vs. this
Technescan HDP 3.15 mgthis 69945-0091-20 Curium 5 vials FDA listed
About this product: this is the brand-name version. We did not find an FDA-approved generic match for this exact strength, form and route.
Where does this data come from?
Equivalents are other NDCs of the same ingredient, form and route from the openFDA NDC Directory, ranked least-expensive-first by NADAC. Therapeutic-equivalence (AB) ratings come from the FDA Orange Book; biologics use the FDA Purple Book for biosimilar & interchangeable status.

Availability & generic status

🏛️
2015
On the market since
Oct 2015
📍
2026
Currently FDA-listed
11 years listed
🔒
·
No generic listed yet
brand only
ℹ️No FDA-approved generic found

We did not find an FDA-approved generic match for this exact strength, form and route.

Where does this data come from?
Patents and exclusivity from the FDA Orange Book (small-molecule drugs), refreshed from public FDA data. Generic launch timing is an estimate, not a guarantee.

🔬 Reported adverse events (FAERS)

Read carefully: FAERS reports are voluntary and unverified. Counts are not incidence, do not establish causation, are subject to reporting bias, and cannot be used to compare one drug to another. Shown for signal context only. Reports for Technescan HDP (this brand).

Top reported reactions

Nausea16
Bone Scan Abnormal14
Injection Site Pain10
Headache9
Injection Site Swelling8
Injection Site Erythema7
Injection Site Extravasation7

Age at onset

Adult1
Elderly1

Reporter sex

135 reports
Male · 28%
Female · 70%
Unknown · 2%

Serious outcomes

Hospitalization18
Disabling4
Death3
Life-threatening1
Reports over time (by year) — tap or hover for the count & year
2019 2021 2023 2026 66 1
Most recent year is provisional (FAERS lags ~3 months).
Where does this data come from?
Adverse-event reports from the FDA Adverse Event Reporting System (FAERS) via openFDA. FAERS reports are voluntary and unverified — counts are not incidence and don’t establish causation.

📦 Packaging — all sizes for this product

Package NDCDescription Marketing startStatus
69945-0091-20 You're viewing this 5 VIAL in 1 CELLO PACK (69945-091-20) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL 2015-10-13 Active
69945-0091-40 30 VIAL in 1 CARTON (69945-091-40) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL 2015-10-13 Active

Pack size FAQ

What quantity is in NDC 69945-0091-20?
NDC 69945-0091-20 contains 5 vials — 5 vial in 1 cello pack / 1 injection, powder, lyophilized, for solution in 1 vial.
What is the difference between NDC 69945-0091-20 and NDC 69945-0091-40?
Both are Technescan HDP Technetium Tc 99m Oxidronate 3.15 mg Injection, Powder, Lyophilized, For Solution — the drug itself is identical. NDC 69945-0091-20 is the 5 vials package, while NDC 69945-0091-40 is the 30 vials package.
What NDC number is used to bill for this package of Technescan HDP Technetium Tc 99m Oxidronate 3.15 mg Injection, Powder, Lyophilized, For Solution?
Bill NDC 69945-0091-20 — the 11-digit billing format is 69945009120. Pharmacy and medical claims use the 11-digit form; the FDA label may print a shorter form of the same code.

🧭 About this NDC listing & data coverage

Finished prescription product
What data is (and isn’t) available for this NDC — tap to expand
NDC identity (package / product / labeler codes) ✓ Available
Labeler ✓ Available
Product & package description ✓ Available
Marketing category & status ✓ Available
Active ingredient / dosage form / route ✓ Available
FDA label (SPL via DailyMed) ✓ Available
Package photos ✓ Available
Inactive ingredients (structured) ✓ Available
NADAC pharmacy acquisition price (CMS) — Not published for this NDC CMS publishes NADAC only for NDCs reported in its retail-pharmacy survey.
Orange Book / therapeutic-equivalence data — Not published for this NDC Applies only to products approved under an NDA/ANDA; many listings are out of scope.
HCPCS J-code billing crosswalk — Not published for this NDC Most self-administered / retail products have no J-code — that is normal.
Medicaid utilization (CMS SDUD) — Not published for this NDC CMS reports utilization only for NDCs with Medicaid claims above its privacy threshold.
“Not published” reflects what the public FDA / CMS / NLM sources provide for this exact package code — it is a property of the data feeds, not a judgment about the product.

Questions about this listing

Why is there no price listed?
The pricing shown on our NDC pages comes from CMS NADAC, a voluntary survey of retail community pharmacy invoices. CMS does not publish a NADAC for every NDC — packages outside the retail survey (institutional and hospital products, bulk packages, discontinued items, and many OTC items) may never receive one. A missing price reflects the survey's scope, not this product's actual cost, and does not mean the product is free or unavailable.
Is the NDC printed on the package the same as the 11-digit billing NDC?
Yes, they identify this exact package in different formats. The FDA registers it as 69945-091-20, which is what is printed on the packaging and shown on DailyMed. Insurance claims use a fixed 11-digit 5-4-2 format, so the short segment is padded with a leading zero: 69945-0091-20, written without dashes as 69945009120. The Identity section at the top of this page lists every form of this code.
What do the three segments of this NDC mean?
In 69945-0091-20, the first segment (69945) is the labeler code FDA assigned to Curium US LLC; the middle segment (0091) identifies this specific product — its ingredient, strength, and dosage form; and the last segment (20) identifies this exact package size and type. Together they name one specific package of one specific product.
Is this package still being marketed?
Yes, per the latest FDA NDC Directory data on this page: this package is listed as actively marketed, with no marketing end date reported by Curium US LLC. Listing status can change — the directory data on this page refreshes weekly.
Does this product come in other package sizes?
Yes — the FDA directory lists 1 other package presentation of this same product, including 30 vials (69945-0091-40). Each has its own NDC and its own page — see the package list near the top of this page.
Who lists this product with the FDA?
Curium US LLC is the labeler of record for this NDC — the company under whose FDA-assigned code the package is listed. The labeler may be the manufacturer itself or a distributor marketing the product under its own code.
Do I need a prescription for this product?
This NDC is listed with FDA as a prescription product, so it is dispensed under a prescriber's order. Your pharmacist can tell you whether any over-the-counter forms of the same medication exist.
This page identifies an FDA-listed package (the NDC) and reports public regulatory and pricing data about the listing. It is reference information, not a medical recommendation — talk to your pharmacist or prescriber about your own medication.
Where does this data come from?
Listing facts (marketing category, packager status, marketing dates) from the FDA openFDA NDC Directory; label availability from DailyMed; pricing coverage from CMS NADAC; equivalence scope from the FDA Orange Book.

📄 Full prescribing information FDA SPL

The complete FDA label for this product — the official prescribing information, verbatim, section by section. Jump with a chip, search within the label, or expand everything.
🎯 Indications and Usage 28 words

INDICATIONS AND USAGE Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in adult and pediatric patients.

⏱️ Dosage and Administration ~3 min read

DOSAGE AND ADMINISTRATION Radiation Safety – Drug Handling After radiolabeling of Technescan HDP, the reaction vial contains Technetium Tc 99m Oxidronate Injection. Handle Technetium Tc 99m Oxidronate Injection with appropriate safety measures to minimize radiation exposure. (See PRECAUTIONS, General .) Use waterproof gloves, effective radiation shielding, and other appropriate safety measures when preparing and handling Technetium Tc 99m Oxidronate Injection.

Radiopharmaceuticals should be used by or under the control of healthcare providers who are qualified by specific training and experience in the safe use and handling of radionuclides, and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides. Recommended Dosage Adults The recommended amount of radioactivity of Technetium Tc 99m Oxidronate Injection in adults is 555 MBq (15 mCi) with a range of 370 MBq to 740 MBq (10 mCi to 20 mCi). The maximum dose of oxidronate sodium in adults is 2 mg.

Pediatric Patients The recommended amount of radioactivity of Technetium Tc 99m Oxidronate Injection in pediatric patients is

7.4MBq/kg to 13 MBq/kg (0.20 mCi/kg to 0.35 mCi/kg). The recommended minimum and maximum activity in pediatric patients are 37 MBq (1 mCi) and 740 MBq (20 mCi), respectively. The maximum dose of oxidronate sodium in pediatric patients is 2 mg.

Administration Instructions Measure the patient dose with a dose calibrator just prior to administration. Administer the dose intravenously by slow injection 1 hour to 4 hours before imaging. To minimize radiation dose to the bladder, encourage the patients to drink fluids before and after administration of Technetium Tc 99m Oxidronate Injection and to void immediately before the examination and as often thereafter as possible for the next 6 hours.

(See PRECAUTIONS, General .) Directions for Drug Preparation Procedural Precautions The contents of the vial are intended only for use in the preparation of Technetium Tc 99m Oxidronate Injection and are NOT to be administered directly to the patient. The components of the kit are sterile and non-pyrogenic. Follow the directions carefully and adhere to strict aseptic procedures during preparation.

Sodium pertechnetate Tc 99m injection that contains an oxidizing agent or 0.9% sodium chloride injection containing preservatives is not suitable for use in the preparation of Technetium Tc 99m Oxidronate Injection. Wear waterproof gloves during the entire preparation procedure and during subsequent patient dose withdrawals from the reaction vial. Make all transfers of sodium pertechnetate Tc 99m injection using an adequately shielded syringe.

Keep the prepared Technetium Tc 99m Oxidronate Injection in the lead vial shield with fitted lead cover in place during the useful life of the radioactive preparation. Make all withdrawals and injection of the Technetium Tc 99m Oxidronate Injection with an adequately shielded syringe. If the dose is for a single adult patient or for pediatric patients, see Directions for the Preparation of a Single Adult Dose or Pediatric Dose(s).

Directions for the Preparation of Adult Doses Remove the plastic disc from the Technescan HDP vial and swab the rubber septum with an alcohol swab or a suitable bacteriostatic agent to disinfect the surface. Place the vial in a lead vial shield. Add 3 mL to 6 mL of sodium pertechnetate Tc 99m injection and secure with a fitted lead cover.

In choosing the amount of sodium pertechnetate Tc 99m injection radioactivity to be used, the number of doses desired, the activity of each dose, and radioactive decay must be taken into account. The recommended maximum activity of sodium pertechnetate Tc 99m injection to be added to the vial is 11,100 MBq (300 mCi). Shake the vial gently, for approximately 30 seconds, to ensure complete dissolution.

Using proper shielding, visually inspect the reaction vial. The resulting solution should be clear and free…

Contraindications 3 words

CONTRAINDICATIONS None known.

⚠️ Warnings 132 words

WARNINGS Technetium Tc 99m oxidronate may cause life-threatening hypersensitivity reactions. Have cardiopulmonary resuscitation equipment and personnel available and monitor all patients for hypersensitivity reactions. (See ADVERSE REACTION S .) Technetium Tc 99m oxidronate is known to complex cations such as calcium.

Particular caution should be used with patients who have or who may be predisposed to hypocalcemia. The biodistribution of technetium Tc 99m oxidronate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality.

High levels of these cations may be caused by concomitant medications or medical conditions (e.g., iron overload, hypercalcemia, etc.). Most cases were observed after iron infusion. (See PRECAUTIONS, Drug Interactions .)

🤒 Adverse Reactions 30 words

ADVERSE REACTIONS The following adverse reactions associated with the use of Technescan HDP have been reported: hypersensitivity reactions, including life-threatening reactions, as well as nausea, vomiting, and injection site reactions.

🔄 Drug Interactions ~2 min read

Drug Interactions The biodistribution of technetium Tc 99m oxidronate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. In patients with high levels of these cations caused by concomitant medications, particularly patients receiving iron infusions, consider performing an imaging study with technetium Tc 99m oxidronate injection once the cation levels have normalized (e.g., after 3 to 5 half-lives of the cation).

(See WARNINGS .) Carcinogenesis, Mutagenesis, Impairment of Fertility No long-term animal studies have been performed to evaluate carcinogenic or mutagenic potential or whether technetium Tc 99m oxidronate affects fertility in males and females. Pregnancy Animal reproduction studies have not been conducted with technetium Tc 99m oxidronate. It is also not known whether technetium Tc 99m oxidronate can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity.

All radiopharmaceuticals, including Tehnescan HDP, have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose. If considering Technescan HDP administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from technetium Tc 99m oxidronate and the gestational timing of exposure. Nursing Mothers Technetium-99m is excreted in human milk during lactation, therefore formula feedings should be substituted for breast feedings.

Pediatric Use Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in pediatric patients. The relatively higher effective dose and radiation exposure of the epiphyses in growing bone should be considered in pediatric patients. (See DOSAGE AND ADMINISTRATION , Radiation Dosimetry ).

Geriatric Use This drug is known to be substantially excreted by the kidney, and the risk of toxic reactions to this drug may be greater in patients with impaired renal function. Because elderly patients are more likely to have decreased renal function, care should be taken in dose selection, and it may be useful to monitor renal function.

🤰 Pregnancy 99 words

Pregnancy Animal reproduction studies have not been conducted with technetium Tc 99m oxidronate. It is also not known whether technetium Tc 99m oxidronate can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. All radiopharmaceuticals, including Tehnescan HDP, have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose.

If considering Technescan HDP administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from technetium Tc 99m oxidronate and the gestational timing of exposure.

🧒 Pediatric Use 53 words

Pediatric Use Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in pediatric patients. The relatively higher effective dose and radiation exposure of the epiphyses in growing bone should be considered in pediatric patients. (See DOSAGE AND ADMINISTRATION , Radiation Dosimetry ).

🧓 Geriatric Use 58 words

Geriatric Use This drug is known to be substantially excreted by the kidney, and the risk of toxic reactions to this drug may be greater in patients with impaired renal function. Because elderly patients are more likely to have decreased renal function, care should be taken in dose selection, and it may be useful to monitor renal function.

🆘 Overdosage 32 words

OVERDOSAGE In the event of the administration of an overdose of Technetium Tc 99m Oxidronate Injection, encourage patients to drink fluids and void frequently to reduce the radiation dose to the patient.

🧬 Clinical Pharmacology 93 words

CLINICAL PHARMACOLOGY During the 24 hours following injection, technetium Tc 99m oxidronate is cleared from blood and other non-osseous tissues and accumulates in the skeleton and urine in humans. Blood levels are about 10% of the injected dose at one hour post-injection and continue to fall to about 6%, 4% and 3% at 2, 3, and 4 hours, respectively. When measured at 24 hours following its administration, skeletal retention is approximately 50% of the injected dose.

Technetium Tc 99m oxidronate exhibits its greatest affinity for areas of altered osteogenesis and actively metabolizing bone.

📦 How Supplied / Storage and Handling 155 words

HOW SUPPLIED Technescan HDP (kit for the preparation of technetium Tc 99m oxidronate injection) contains 3.15 mg oxidronate sodium as a white lyophilized powder in a multiple-dose vial. Technescan HDP is available as: • 5 vials per carton (NDC 69945-091-20) • 30 vials per carton (NDC 69945-091-40) Before radiolabeling, store at 20°C to 25°C (68°F to 77°F) [see USP Controlled Room Temperature]. After radiolabeling, store vial upright in appropriate shielding at 20°C to 25°C (68°F to 77°F) [see USP Controlled Room Temperature].

Use within 8 hours of radiolabeling. Dispose of unused products in accordance with appropriate regulations. This reagent kit is for distribution to persons licensed by the U.S.

Nuclear Regulatory Commission or the relevant regulatory authority of an Agreement State. Manufactured by: Curium US LLC 2703 Wagner Place Maryland Heights, MO 63043 Made in USA ©2025 Curium US LLC. Technescan™, Curium™, and the Curium logo are trademarks of a Curium company.

A091I0 Revised: 11/2025

📋 Description 149 words

DESCRIPTION Drug Characteristics Technescan™ HDP (kit for the preparation of technetium Tc 99m oxidronate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection. Each vial contains 3.15 mg oxidronate sodium and 0.258 mg, minimum, stannous chloride (SnCl 2 •2H 2 O), 0.297 mg, theoretical, stannous chloride (SnCl 2 •2H 2 O) with 0.343 mg, maximum, tin chloride [stannous and stannic] dihydrate as SnCl 2 •2H 2 O, and the following inactive ingredients: 0.84 mg gentisic acid as a stabilizer and 30 mg sodium chloride.

The pH is adjusted with hydrochloric acid and/or sodium hydroxide. The pH of the radiolabeled drug is between 4.0 and 5.5. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen.

The chemical structure of oxidronate sodium is: The structure of the technetium Tc 99m oxidronate complex is unknown. The chemical structure of oxidronate sodium is:

Source: FDA Structured Product Labeling, mirrored from DailyMed / openFDA. Prefer the government’s original formatting? View this label on DailyMed ↗
For educational and professional reference only — not medical advice. Pricing reflects published NADAC and CMS ASP (free public data) and may differ from your acquisition cost; always verify before billing or dispensing.