Technescan HDP Technetium Tc 99m Oxidronate 3.15 mg Injection, Powder, Lyophilized, For Solution, 5 vials
🆔 Identity & classification
Where does this data come from?
🏭 Manufacturer & labeler
Where does this data come from?
🩺 Clinical
Patient education
Supplement & herbal interactions
Where does this data come from?
Ask a licensed pharmacist directly — free, answered by our team.
🧪 Inactive Ingredients / Excipients
Inactive ingredients, also called excipients, are components of the drug product other than the active ingredient. They may include fillers, dyes, coatings, preservatives, flavors, or other formulation ingredients.
💡 Tap an ingredient (hover on desktop) to see what it is and why it’s used.
-
UNII VP36V95O3T
Gentisic acid is a naturally occurring organic compound used in pharmaceuticals as a buffer and pH stabilizer. It helps maintain the correct acidity level in medicines to improve stability and ensure consistent performance.
-
UNII 451W47IQ8X
Sodium chloride is common table salt. It's used in medicines as a buffer to maintain proper pH, as a filler to add bulk, or to adjust the osmotic balance in liquid formulations.
-
UNII 1BQV3749L5
Stannous chloride is a tin-based chemical compound used as a reducing agent and antioxidant in pharmaceuticals. It helps prevent oxidation of active ingredients and stabilizes certain formulations, particularly in products requiring preservation of potency.
3 inactive ingredients listed in the exact product block matched to this NDC.
Where does this data come from?
ingredient classCode="IACT" elements from the exact product block matched by this NDC. Label-section narrative from DailyMed / the openFDA label index is shown separately when available.Inactive ingredient FAQ
Are inactive ingredients the same for every manufacturer?
Why might an inactive ingredient be missing?
Can inactive ingredients matter?
💲 Pricing
A drug doesn't have one price. Each row is a different public payment system, and none is what you'd pay at the counter — that depends on your insurance. The ⓘ on each row explains what it measures.
| Price system | Per mL | Per package |
|---|---|---|
| Retail pharmacies payNADAC · weekly | Not in the retail survey — common for institutional, discontinued, or low-volume packs. | |
| Medicaid paysCMS SDUD · 12 mo | No recent Medicaid claims on file for this NDC — rare and low-volume NDCs are suppressed in the public data. | |
| Medicare drug plans payPart D · quarterly | No Part D plan price is available for this NDC in our data. | |
Where does this data come from?
🔁 Therapeutic equivalents
| Product | Labeler | Pack | NADAC/unit | TE | Status | Price vs. this |
|---|---|---|---|---|---|---|
| Technescan HDP 3.15 mgthis 69945-0091-20 | Curium | 5 vials | — | — | FDA listed | — |
Where does this data come from?
⏳ Availability & generic status
We did not find an FDA-approved generic match for this exact strength, form and route.
Where does this data come from?
🔬 Reported adverse events (FAERS)
Top reported reactions
Age at onset
Reporter sex
Serious outcomes
Where does this data come from?
📦 Packaging — all sizes for this product
| Package NDC | Description | Marketing start | Status |
|---|---|---|---|
| 69945-0091-20 You're viewing this | 5 VIAL in 1 CELLO PACK (69945-091-20) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL | 2015-10-13 | Active |
| 69945-0091-40 | 30 VIAL in 1 CARTON (69945-091-40) / 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL | 2015-10-13 | Active |
Pack size FAQ
What quantity is in NDC 69945-0091-20?
What is the difference between NDC 69945-0091-20 and NDC 69945-0091-40?
What NDC number is used to bill for this package of Technescan HDP Technetium Tc 99m Oxidronate 3.15 mg Injection, Powder, Lyophilized, For Solution?
🧭 About this NDC listing & data coverage
What data is (and isn’t) available for this NDC — tap to expand
| NDC identity (package / product / labeler codes) | ✓ Available |
| Labeler | ✓ Available |
| Product & package description | ✓ Available |
| Marketing category & status | ✓ Available |
| Active ingredient / dosage form / route | ✓ Available |
| FDA label (SPL via DailyMed) | ✓ Available |
| Package photos | ✓ Available |
| Inactive ingredients (structured) | ✓ Available |
| NADAC pharmacy acquisition price (CMS) | — Not published for this NDC CMS publishes NADAC only for NDCs reported in its retail-pharmacy survey. |
| Orange Book / therapeutic-equivalence data | — Not published for this NDC Applies only to products approved under an NDA/ANDA; many listings are out of scope. |
| HCPCS J-code billing crosswalk | — Not published for this NDC Most self-administered / retail products have no J-code — that is normal. |
| Medicaid utilization (CMS SDUD) | — Not published for this NDC CMS reports utilization only for NDCs with Medicaid claims above its privacy threshold. |
Questions about this listing
Why is there no price listed?
Is the NDC printed on the package the same as the 11-digit billing NDC?
What do the three segments of this NDC mean?
Is this package still being marketed?
Does this product come in other package sizes?
Who lists this product with the FDA?
Do I need a prescription for this product?
Where does this data come from?
📄 Full prescribing information FDA SPL
🎯 Indications and Usage ▾
INDICATIONS AND USAGE Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in adult and pediatric patients.
⏱️ Dosage and Administration ▾
DOSAGE AND ADMINISTRATION Radiation Safety – Drug Handling After radiolabeling of Technescan HDP, the reaction vial contains Technetium Tc 99m Oxidronate Injection. Handle Technetium Tc 99m Oxidronate Injection with appropriate safety measures to minimize radiation exposure. (See PRECAUTIONS, General .) Use waterproof gloves, effective radiation shielding, and other appropriate safety measures when preparing and handling Technetium Tc 99m Oxidronate Injection.
Radiopharmaceuticals should be used by or under the control of healthcare providers who are qualified by specific training and experience in the safe use and handling of radionuclides, and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides. Recommended Dosage Adults The recommended amount of radioactivity of Technetium Tc 99m Oxidronate Injection in adults is 555 MBq (15 mCi) with a range of 370 MBq to 740 MBq (10 mCi to 20 mCi). The maximum dose of oxidronate sodium in adults is 2 mg.
Pediatric Patients The recommended amount of radioactivity of Technetium Tc 99m Oxidronate Injection in pediatric patients is
7.4MBq/kg to 13 MBq/kg (0.20 mCi/kg to 0.35 mCi/kg). The recommended minimum and maximum activity in pediatric patients are 37 MBq (1 mCi) and 740 MBq (20 mCi), respectively. The maximum dose of oxidronate sodium in pediatric patients is 2 mg.
Administration Instructions Measure the patient dose with a dose calibrator just prior to administration. Administer the dose intravenously by slow injection 1 hour to 4 hours before imaging. To minimize radiation dose to the bladder, encourage the patients to drink fluids before and after administration of Technetium Tc 99m Oxidronate Injection and to void immediately before the examination and as often thereafter as possible for the next 6 hours.
(See PRECAUTIONS, General .) Directions for Drug Preparation Procedural Precautions The contents of the vial are intended only for use in the preparation of Technetium Tc 99m Oxidronate Injection and are NOT to be administered directly to the patient. The components of the kit are sterile and non-pyrogenic. Follow the directions carefully and adhere to strict aseptic procedures during preparation.
Sodium pertechnetate Tc 99m injection that contains an oxidizing agent or 0.9% sodium chloride injection containing preservatives is not suitable for use in the preparation of Technetium Tc 99m Oxidronate Injection. Wear waterproof gloves during the entire preparation procedure and during subsequent patient dose withdrawals from the reaction vial. Make all transfers of sodium pertechnetate Tc 99m injection using an adequately shielded syringe.
Keep the prepared Technetium Tc 99m Oxidronate Injection in the lead vial shield with fitted lead cover in place during the useful life of the radioactive preparation. Make all withdrawals and injection of the Technetium Tc 99m Oxidronate Injection with an adequately shielded syringe. If the dose is for a single adult patient or for pediatric patients, see Directions for the Preparation of a Single Adult Dose or Pediatric Dose(s).
Directions for the Preparation of Adult Doses Remove the plastic disc from the Technescan HDP vial and swab the rubber septum with an alcohol swab or a suitable bacteriostatic agent to disinfect the surface. Place the vial in a lead vial shield. Add 3 mL to 6 mL of sodium pertechnetate Tc 99m injection and secure with a fitted lead cover.
In choosing the amount of sodium pertechnetate Tc 99m injection radioactivity to be used, the number of doses desired, the activity of each dose, and radioactive decay must be taken into account. The recommended maximum activity of sodium pertechnetate Tc 99m injection to be added to the vial is 11,100 MBq (300 mCi). Shake the vial gently, for approximately 30 seconds, to ensure complete dissolution.
Using proper shielding, visually inspect the reaction vial. The resulting solution should be clear and free…
⛔ Contraindications ▾
CONTRAINDICATIONS None known.
⚠️ Warnings ▾
WARNINGS Technetium Tc 99m oxidronate may cause life-threatening hypersensitivity reactions. Have cardiopulmonary resuscitation equipment and personnel available and monitor all patients for hypersensitivity reactions. (See ADVERSE REACTION S .) Technetium Tc 99m oxidronate is known to complex cations such as calcium.
Particular caution should be used with patients who have or who may be predisposed to hypocalcemia. The biodistribution of technetium Tc 99m oxidronate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality.
High levels of these cations may be caused by concomitant medications or medical conditions (e.g., iron overload, hypercalcemia, etc.). Most cases were observed after iron infusion. (See PRECAUTIONS, Drug Interactions .)
🤒 Adverse Reactions ▾
ADVERSE REACTIONS The following adverse reactions associated with the use of Technescan HDP have been reported: hypersensitivity reactions, including life-threatening reactions, as well as nausea, vomiting, and injection site reactions.
🔄 Drug Interactions ▾
Drug Interactions The biodistribution of technetium Tc 99m oxidronate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. In patients with high levels of these cations caused by concomitant medications, particularly patients receiving iron infusions, consider performing an imaging study with technetium Tc 99m oxidronate injection once the cation levels have normalized (e.g., after 3 to 5 half-lives of the cation).
(See WARNINGS .) Carcinogenesis, Mutagenesis, Impairment of Fertility No long-term animal studies have been performed to evaluate carcinogenic or mutagenic potential or whether technetium Tc 99m oxidronate affects fertility in males and females. Pregnancy Animal reproduction studies have not been conducted with technetium Tc 99m oxidronate. It is also not known whether technetium Tc 99m oxidronate can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity.
All radiopharmaceuticals, including Tehnescan HDP, have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose. If considering Technescan HDP administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from technetium Tc 99m oxidronate and the gestational timing of exposure. Nursing Mothers Technetium-99m is excreted in human milk during lactation, therefore formula feedings should be substituted for breast feedings.
Pediatric Use Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in pediatric patients. The relatively higher effective dose and radiation exposure of the epiphyses in growing bone should be considered in pediatric patients. (See DOSAGE AND ADMINISTRATION , Radiation Dosimetry ).
Geriatric Use This drug is known to be substantially excreted by the kidney, and the risk of toxic reactions to this drug may be greater in patients with impaired renal function. Because elderly patients are more likely to have decreased renal function, care should be taken in dose selection, and it may be useful to monitor renal function.
🤰 Pregnancy ▾
Pregnancy Animal reproduction studies have not been conducted with technetium Tc 99m oxidronate. It is also not known whether technetium Tc 99m oxidronate can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. All radiopharmaceuticals, including Tehnescan HDP, have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose.
If considering Technescan HDP administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from technetium Tc 99m oxidronate and the gestational timing of exposure.
🧒 Pediatric Use ▾
Pediatric Use Technescan HDP, after radiolabeling with sodium pertechnetate Tc 99m, is indicated for skeletal imaging to demonstrate areas of altered osteogenesis in pediatric patients. The relatively higher effective dose and radiation exposure of the epiphyses in growing bone should be considered in pediatric patients. (See DOSAGE AND ADMINISTRATION , Radiation Dosimetry ).
🧓 Geriatric Use ▾
Geriatric Use This drug is known to be substantially excreted by the kidney, and the risk of toxic reactions to this drug may be greater in patients with impaired renal function. Because elderly patients are more likely to have decreased renal function, care should be taken in dose selection, and it may be useful to monitor renal function.
🆘 Overdosage ▾
OVERDOSAGE In the event of the administration of an overdose of Technetium Tc 99m Oxidronate Injection, encourage patients to drink fluids and void frequently to reduce the radiation dose to the patient.
🧬 Clinical Pharmacology ▾
CLINICAL PHARMACOLOGY During the 24 hours following injection, technetium Tc 99m oxidronate is cleared from blood and other non-osseous tissues and accumulates in the skeleton and urine in humans. Blood levels are about 10% of the injected dose at one hour post-injection and continue to fall to about 6%, 4% and 3% at 2, 3, and 4 hours, respectively. When measured at 24 hours following its administration, skeletal retention is approximately 50% of the injected dose.
Technetium Tc 99m oxidronate exhibits its greatest affinity for areas of altered osteogenesis and actively metabolizing bone.
📦 How Supplied / Storage and Handling ▾
HOW SUPPLIED Technescan HDP (kit for the preparation of technetium Tc 99m oxidronate injection) contains 3.15 mg oxidronate sodium as a white lyophilized powder in a multiple-dose vial. Technescan HDP is available as: • 5 vials per carton (NDC 69945-091-20) • 30 vials per carton (NDC 69945-091-40) Before radiolabeling, store at 20°C to 25°C (68°F to 77°F) [see USP Controlled Room Temperature]. After radiolabeling, store vial upright in appropriate shielding at 20°C to 25°C (68°F to 77°F) [see USP Controlled Room Temperature].
Use within 8 hours of radiolabeling. Dispose of unused products in accordance with appropriate regulations. This reagent kit is for distribution to persons licensed by the U.S.
Nuclear Regulatory Commission or the relevant regulatory authority of an Agreement State. Manufactured by: Curium US LLC 2703 Wagner Place Maryland Heights, MO 63043 Made in USA ©2025 Curium US LLC. Technescan™, Curium™, and the Curium logo are trademarks of a Curium company.
A091I0 Revised: 11/2025
📋 Description ▾
DESCRIPTION Drug Characteristics Technescan™ HDP (kit for the preparation of technetium Tc 99m oxidronate injection) is a radioactive diagnostic drug for intravenous use after radiolabeling with sodium pertechnetate Tc 99m injection. Each vial contains 3.15 mg oxidronate sodium and 0.258 mg, minimum, stannous chloride (SnCl 2 •2H 2 O), 0.297 mg, theoretical, stannous chloride (SnCl 2 •2H 2 O) with 0.343 mg, maximum, tin chloride [stannous and stannic] dihydrate as SnCl 2 •2H 2 O, and the following inactive ingredients: 0.84 mg gentisic acid as a stabilizer and 30 mg sodium chloride.
The pH is adjusted with hydrochloric acid and/or sodium hydroxide. The pH of the radiolabeled drug is between 4.0 and 5.5. The vial contains a sterile, non-pyrogenic, lyophilized powder packaged under nitrogen.