💉image loading
(from DailyMed)

Pulmotech MAA kit for the preparation of technetium Tc 99m albumin aggregated 2 mg/15mL Injection, Powder, Lyophilized, For Suspension — NDC 69945-139-40 (Billing 69945-0139-40)

by Curium US LLC · 30 VIAL, MULTI-DOSE in 1 CARTON / 15 mL in 1 VIAL, MULTI-DOSE

This is a package of Pulmotech MAA kit for the preparation of technetium Tc 99m albumin aggregated 2 mg/15mL Injection, Powder, Lyophilized, For Suspension from Curium US LLC, marketed since Mar 2020 and currently FDA-listed.

NDC 69945-0139-40
🏷️ FDA NDC (as labeled) 69945-139-40 billing pads the product segment with a zero
This package
Contains15 mL in 1 vial, multi-dose Medicaid pays$7.52 / unit · 12 mo Per package$3,383.69 / 450 ml · Medicaid Pack sizes2 compare ↓
Rx only Brand On market Non-controlled ⇄ Compare with another NDC
🗂️ FDA directory synced Oct 1, 2026 · this listing last changed Jul 24, 2026 · sources: openFDA · FDA label (DailyMed) · FDA Orange & Purple Book · First Databank · CMS NADAC, ASP, Medicare & Medicaid · RxNorm
📋 All sources & update times →

NDC database record

One package, one record: these facts belong to NDC 69945-139-40 alone.

Record
FDA NDC Directory package listing · Human prescription drug
Code segments
69945 labeler · 139 product · 40 package
Package marketed since
Mar 20, 2020
Sample package
No — commercial package
Listing certified through
Dec 31, 2026
Barcode (UPC-A, from the NDC)
3 6994513940 5
Medicaid fills, this package
29 prescriptions in the last four reported quarters
FDA record last changed
Jul 24, 2026

Identity & classification

Regulatory identifiers FDA, NLM and CMS codes for this package

FDA NDC (as labeled) 69945-139-40
Product NDC 69945-139
11-digit billing NDC 69945013940
UNII 799C8VF17R
Application # BLA210089
SPL Set ID a8b7adf0-2c6b-4acd-96d3-a099306951a0
DEA schedule Non-controlled
Marketing category BLA
Marketing status On market
FDA listing status Listed (active directory)
Marketing start 2020-03-20
Route INTRAPERITONEAL, INTRAVENOUS
Dosage form INJECTION, POWDER, LYOPHILIZED, FOR SUSPENSION
Substance ALBUMIN AGGREGATED
Biologic (Purple Book) 351(a)

Drug-database identifiers Medi-Span GPI and First Databank GCN / HICL / AHFS classification

GCN Seq No 080953
GCN 47943
HICL code 024536
Ingredient (HICL) Kit For Prep Of Tc-99M/Albumin
HIC1 code Z
Therapeutic class — broad (HIC1) Body As A Whole
HIC2 code Z9
Therapeutic class — intermediate (HIC2) Unclassified Drugs
HIC3 code Z9D
Therapeutic class — specific (HIC3) Diagnostic Preparations,Miscellaneous
AHFS code 36:68.00.00
AHFS class Roentgenography And Other Imaging Agents
FDB label name PULMOTECH MAA PREPARATION KIT
FDB brand name Pulmotech Maa
Legend status F — Federal legend — prescription drug or device
Quick answers
  • GSN (GCN sequence number): 080953
  • GCN: 47943
  • HICL (First Databank): 024536
  • AHFS class code: 36:68.00.00
Why two NDCs? The FDA registers this code as 69945-139-40 — a 5-3-2 layout, and that's what's printed on the package and shown on DailyMed. For insurance claims, every NDC is standardized to a uniform 11-digit 5-4-2 format by adding a zero to the product segment → 69945-0139-40. Same drug, same package — only the format differs.
Where does this data come from?
Identifiers from the FDA openFDA NDC Directory and Structured Product Labeling; RxCUI from RxNorm (NLM); GPI from Medi-Span; GCN / HIC / AHFS / legend from First Databank.

Clinical

Label name PULMOTECH MAA PREPARATION KIT Ingredient Kit For Prep Of Tc-99M/Albumin
Where does this data come from?
Plain-language summary from MedlinePlus (U.S. National Library of Medicine); supplement & herbal interactions and nutrient depletion data from the Natural Medicines database; our full guide is HelloPharmacist editorial content.

Pricing

A drug doesn't have one price. Each row is a different public payment system, and none is what you'd pay at the counter — that depends on your insurance. The ⓘ on each row explains what it measures.

Price systemPer mLPer package
Retail pharmacies payNADAC · weekly Not in the retail survey — common for institutional, discontinued, or low-volume packs.
Medicaid paysCMS SDUD · 12 mo $7.52 $3,383.69 / 450 ml
Medicare drug plans payPart D · quarterly No Part D plan price is available for this NDC in our data.
Where does this data come from?
NADAC (National Average Drug Acquisition Cost) is the CMS weekly pharmacy-acquisition-cost survey — what pharmacies pay. ASP (Average Sales Price) is the CMS Medicare Part B drug-payment file, published quarterly. Medicaid pays is computed by us from CMS State Drug Utilization Data (total reimbursed ÷ units, trailing 12 months) — gross of rebates and inclusive of dispensing fees, so it reflects what Medicaid paid, not an acquisition cost. Medicare drug plans pay is the median negotiated point-of-sale unit cost across plans listing this NDC in the CMS quarterly Prescription Drug Plan pricing files, before rebates. The VA pays is the federal contract price (FSS, and the statutory Big 4 ceiling where listed) from the VA National Acquisition Center pharmaceutical price file. All are free public government data; each measures a different payer, so the figures are not directly comparable.

Packaging — all sizes for this product

Package NDCDescription Marketing startMarketing endStatus
69945-0139-20 69945-139-20 Main listing 5 VIAL, MULTI-DOSE in 1 CELLO PACK / 15 mL in 1 VIAL, MULTI-DOSE 2020-03-20 — Active
69945-0139-40 You're viewing this 30 VIAL, MULTI-DOSE in 1 CARTON / 15 mL in 1 VIAL, MULTI-DOSE 2020-03-20 — Active

Pack size FAQ

What quantity is in this package?
This package is listed by the FDA — 30 vial, multi-dose in 1 carton / 15 ml in 1 vial, multi-dose.
What NDC number is used to bill for this package of Pulmotech MAA kit for the preparation of technetium Tc 99m albumin aggregated 2 mg/15mL Injection, Powder, Lyophilized, For Suspension?
Use the 11-digit billing form listed in the identifiers section of this page. Pharmacy and medical claims use the 11-digit form; the FDA label may print a shorter form of the same code.

Therapeutic equivalents

ProductLabelerPackNADAC/unitTEStatusPrice vs. this
Pulmotech MAA 2 mg/15mLthis 69945-0139-40 Curium 30 vials — — FDA listed —
About this product: this is a biologic. Biologics don't have small-molecule generics — competition comes from FDA-licensed biosimilars (shown above), not generics.
Where does this data come from?
Equivalents are other NDCs of the same ingredient, form and route from the openFDA NDC Directory, ranked least-expensive-first by NADAC. Therapeutic-equivalence (AB) ratings come from the FDA Orange Book; biologics use the FDA Purple Book for biosimilar & interchangeable status.

Availability & biosimilar status

🏛️
2020
First FDA approval
Mar 2020
📍
2026
Currently FDA-listed
6 years listed
🛡️
2032
Latest patent/protection listed
not a guaranteed launch date
🧬Biologic — competition comes from biosimilars

Biologics have no small-molecule generics; biosimilar competition is tracked in the FDA Purple Book.

🛡️ Latest patent/protection date listed: FDA patent/protection data lists protections through Mar 2032. This may affect when biosimilars become widely available, but it is not a guaranteed launch date.
📅 FDA approved Mar 20, 2020 ⏳ ~5.5 yr to latest listed protection

Why the date isn’t exact: Biosimilar timing can change because patents may be challenged, settled, licensed, added or removed, and litigation can move the real date earlier or later.

Patents & exclusivity — FDA Purple Book
Exclusivity RefProduct
2020 2022 2024 2026 2028 2030 2032
Today
LOE
Biologic patent Exclusivity
🏛️Reference-product exclusivity
A flat 12 years of FDA market protection from first licensure. No biosimilar can be licensed before it ends — regardless of patents.
🧪Listed biologic patents
Patents the reference maker lists covering the molecule, formulation, or manufacturing. A biosimilar generally can’t launch until these resolve.
🔁Interchangeability
An interchangeable biosimilar may be substituted at the pharmacy (state laws vary). The first one can earn its own exclusivity period.
🛈 What do these terms mean?
Biologic patent
A patent the reference product’s maker has publicly listed. A biosimilar generally can’t launch until these expire — unless they’re invalidated or resolved in a settlement.
Reference-product exclusivity
A flat 12 years of FDA market protection from the biologic’s first licensure (the BPCIA). No biosimilar can be licensed before it ends, regardless of patents.
Interchangeable exclusivity
The first interchangeable biosimilar can earn a period as the only interchangeable version (pharmacists can substitute it without the prescriber).
Earliest biosimilar (LOE)
The latest of all the dates above — the soonest a biosimilar can realistically reach the market. Litigation and settlements can move it earlier.

Biologics have no small-molecule “generics” — competition comes from FDA-licensed biosimilars, tracked in the FDA Purple Book.

FDA exclusivity
CodeWhat it grantsExpires
RefProductReference-product exclusivity (12-year, BPCIA) — no biosimilar can be licensed before this dateMar 20, 2032
Common questions
Is there a biosimilar for PULMOTECH MAA PREPARATION KIT?
No FDA-licensed biosimilar is currently listed for this biologic in the FDA Purple Book.
Why do different websites show different biosimilar dates?
Biosimilar availability isn’t based on one single date. Some sources use the reference-product exclusivity, some use the last listed patent, and patent litigation, settlements, and licenses can all change the real-world launch date. This page shows the underlying Purple Book dates so you can see why estimates differ.
Can a biosimilar launch before the last patent expires?
Sometimes. A biosimilar maker may settle with the reference manufacturer or receive a license to launch earlier. In other cases, the last listed protection delays competition.
What does “current Purple Book estimate” mean?
It means we’re using the latest patent and exclusivity dates currently listed in the FDA Purple Book. It is not a guaranteed launch date.
What does “FDA listed” mean?
It means the product appears in the FDA’s official directory. That’s a good sign a product exists for the U.S. market, but on its own it does not confirm a pharmacy can get it today. Where we have recent retail pricing data, we label it “Availability likely” instead.
What does a patent or protection date mean here?
It’s the latest date currently listed in the FDA Purple Book for a patent or exclusivity on the reference biologic. It can affect when a biosimilar becomes widely available — but it is not a guaranteed launch date. Settlements and licenses can move the real date earlier or later.
Built from the FDA Purple Book Patent List (patents the reference-product sponsor has publicly listed under the BPCIA) plus reference-product exclusivity. Biosimilars cannot launch until these clear; patent litigation and settlements can shift the real date. Biologics have no small-molecule generics — competition comes from FDA-licensed biosimilars, not the Orange Book.
Where does this data come from?
Patents and exclusivity from the FDA Purple Book (biologics), refreshed from public FDA data. Biosimilar launch timing is an estimate, not a guarantee.

Inactive Ingredients / Excipients

Inactive ingredients, also called excipients, are components of the drug product other than the active ingredient. They may include fillers, dyes, coatings, preservatives, flavors, or other formulation ingredients.

💡 Tap an ingredient (hover on desktop) to see what it is and why it’s used.

  • 7.1 mg / 15 mL UNII ZIF514RVZR
    A protein derived from human blood plasma. In medicines, it acts as a stabilizer and binder, helping maintain drug potency and form, and may improve how the medication disperses or dissolves in the body.
  • 9 mg / 15 mL UNII 451W47IQ8X
    Sodium chloride is common table salt. It's used in medicines as a buffer to maintain proper pH, as a filler to add bulk, or to adjust the osmotic balance in liquid formulations.
  • 0.1 mg / 15 mL UNII 1BQV3749L5
    Stannous chloride is a tin-based chemical compound used as a reducing agent and antioxidant in pharmaceuticals. It helps prevent oxidation of active ingredients and stabilizes certain formulations, particularly in products requiring preservation of potency.

3 inactive ingredients listed in the exact product block matched to this NDC.

Where does this data come from?
Data sourced from official FDA Structured Product Labeling (SPL) via DailyMed — ingredient classCode="IACT" elements from the exact product block matched by this NDC. Label-section narrative from DailyMed / the openFDA label index is shown separately when available.

Inactive ingredient FAQ

Are inactive ingredients the same for every manufacturer?
No. Inactive ingredients can differ by manufacturer, dosage form, strength, and package / product version.
Why might an inactive ingredient be missing?
Some SPLs do not provide a complete structured inactive-ingredient list, and older or unusual labels may only include the information in narrative text.
Can inactive ingredients matter?
Yes. They can matter for allergies, intolerances, dyes, gluten / lactose concerns, preservatives, and formulation differences — but confirm with a pharmacist or the manufacturer when it’s clinically important.

Manufacturer & labeler

LabelerCurium US LLC
FDA applicationBLA210089 (BLA)
Labeler code69945
First marketedMar 2020
Product typeHuman Prescription Drug
Portfolio34 products on file
The labeler markets the product; the application holder owns the FDA approval. They’re often the same company but can differ (e.g. a repackager or an authorized generic). A mailing address / phone appears here when the manufacturer includes it in the product’s FDA label (not all do).
Where does this data come from?
Labeler, application holder and registered establishment from the FDA openFDA NDC Directory and Drugs@FDA; address/contact from the product’s FDA label.

Full prescribing information FDA SPL

The complete FDA label for this product — the official prescribing information, verbatim, section by section. Very long sections are excerpted here and marked; the full text is on DailyMed (linked in the sources below). Jump with a chip, search within the label, or expand everything.
🎯 Indications and Usage 92 words ▾

1 INDICATIONS AND USAGE PULMOTECH MAA, after radiolabeling with technetium-99m, is indicated for: Lung scintigraphy as an adjunct in the evaluation of pulmonary perfusion in adults and pediatric patients. Peritoneovenous shunt scintigraphy as an aid in the evaluation of its patency in adults. PULMOTECH MAA, after radiolabeling with technetium-99m is a radioactive diagnostic agent indicated for: Lung scintigraphy as an adjunct in the evaluation of pulmonary perfusion in adults and pediatric patients.

( 1 ) Peritoneovenous shunt scintigraphy as an aid in the evaluation of its patency in adults. ( 1 )

⏱️ Dosage and Administration ~3 min read ▾

2 DOSAGE AND ADMINISTRATION For lung perfusion scintigraphy, the following recommended activity is administered by intravenous injection. • Adults : 37 MBq to 148 MBq (1 mCi to 4 mCi) and 200,000 particles to 700,000 particles. ( 2.3 ) • Pediatric patients aged 4 weeks and older : 0.925 MBq/kg to

1.85MBq/kg of body weight (0.025 mCi/kg to 0.05 mCi/kg); the minimum activity is

7.4MBq (0.2 mCi). The number of particles will vary with age and body weight of the pediatric patient. ( 2.3 ) • Pediatric patients aged less than 4 weeks :

7.4 MBq to

18.5MBq (0.2 mCi to 0.5 mCi); 10,000 particles to 50,000 particles. ( 2.3 ) For peritoneovenous shunts scintigraphy in adults: 37 MBq to 111 MBq (1 mCi to 3 mCi) and 200,000 particles to 700,000 particles by intraperitoneal injection. ( 2.4 ) See Full Prescribing Information for radiation safety, patient preparation, drug preparation, administration, imaging, and radiation dosimetry information. ( 2.1 , 2.2 , 2.5 , 2.6 , 2.7 )

2.1Radiation Safety – Drug Handling After radiolabeling of PULMOTECH MAA, the vial contains Technetium Tc 99m Albumin Aggregated Injection. Handle Technetium Tc 99m Albumin Aggregated Injection with appropriate safety measures to minimize radiation exposure [see Warnings and Precautions ( 5.4 )] . Use waterproof gloves, effective radiation shielding, and other appropriate safety measures when preparing and handling Technetium Tc 99m Albumin Aggregated Injection.

Radiopharmaceuticals should be used by or under the control of healthcare providers who are qualified by specific training and experience in the safe use and handling of radionuclides, and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides.

2.2Patient Preparation Instruct patients to drink a sufficient amount of water to ensure adequate hydration prior to administration of Technetium Tc 99m Albumin Aggregated Injection and to continue to drink and void frequently following administration to reduce radiation exposure [see Warnings and Precautions ( 5.4 )] . 2. 3 Recommended Dosage for Lung Perfusion Scintigraphy Adult Patients The recommended activity for lung perfusion scintigraphy in adult patients is 37 MBq to 148 MBq (1 mCi to 4 mCi) by intravenous injection.

The range of particle numbers per single injection should be 200,000 to 700,000 with the recommended number of approximately 350,000. Depending on the activity added and volume of the final radiolabeled product, the volume of the dose may vary from 0.2 mL to 1.9 mL. The number of particles available per dose of Technetium Tc 99m Albumin Aggregated Injection will vary depending on the physical decay of technetium-99m that has occurred.

The number of particles in any dose and volume to be administrated may be calculated as follows: Where: V a = volume to be administered in mL D = desired activity to be administered in MBq (mCi) C = concentration at calibration time of Sodium Pertechnetate Tc 99m Injection to be added to the reaction vial in MBq/mL (mCi/mL) Fr = fraction of Technetium-99m remaining after the time of calibration from Table 6 [see Description ( 11.3 )] P = number of particles in dose to be administered V a = volume to be administered in mL V Tc = volume of Sodium Pertechnetate Tc 99m Injection added to reaction vial in mL N = number of particles per vial.

The number of particles per vial for the lot is located on the vial label. Pediatric Patients Aged 4 Weeks and Older The recommended activity for lung perfusion scintigraphy in pediatric patients aged 4 weeks and older by intravenous injection is based on body weight and ranges from 0.925 MBq/kg to

1.85MBq/kg (0.025 mCi/kg to 0.05 mCi/kg). The minimum recommended dose for lung perfusion scintigraphy in this age is

7.4MBq (0.2 mCi). The number of particles will vary with age and body weight of the pediatric patient. Particle numbers administered in four different age and weight categories are shown in… [Excerpted — this section continues on DailyMed.]

💊 Dosage Forms and Strengths 140 words ▾

3 DOSAGE FORMS AND STRENGTHS Kit for the preparation of Technetium Tc 99m Albumin Aggregated Injection: 2 mg of albumin aggregated as a non-radioactive, white lyophilized powder in a multiple-dose reaction vial for radiolabeling with Sodium Pertechnetate Tc 99m Injection to prepare a suspension of Technetium Tc 99m Albumin Aggregated Injection containing up to

6.85MBq (185 mCi) in 2 to 13 mL volume at time of preparation. Each vial contains 2,000,000 to 4,000,000 particles. Kit for the preparation of Technetium Tc 99m Albumin Aggregated Injection: 2 mg of albumin aggregated as a lyophilized powder in a multiple-dose reaction vial. Upon radiolabeling, it provides a suspension of Technetium Tc 99m Albumin Aggregated Injection containing up to

6.85MBq (185 mCi) in 2 to 13 mL volume at time of preparation. Each vial contains 2,000,000 to 4,000,000 particles. ( 3 )

⛔ Contraindications 55 words ▾

4 CONTRAINDICATIONS PULMOTECH MAA is contraindicated in patients with: Severe pulmonary hypertension [see Warnings and Precautions ( 5.1 ) ]. A history of hypersensitivity to albumin human. Reactions have included anaphylaxis [see Warnings and Precautions ( 5.2 )]. Severe pulmonary hypertension. ( 4 ) A history of hypersensitivity reactions to albumin human. ( 4 )

⚠️ Warnings and Cautions ~2 min read ▾

5 WARNINGS AND PRECAUTIONS Patients with P ulmonary H ypertension : Administer the lowest number of particles possible and have emergency resuscitation equipment available. ( 5.1 ) Hypersensitivity Reactions : Have emergency resuscitation equipment and trained personnel available. Interrupt the administration if a reaction occurs during administration.

Monitor patients. ( 5.2 ) Risk of Temporary Impediment to Blood Flow in Patients with Right-to-Left Heart Shunts : Administer the lowest possible number of particles. ( 5.3 ) Radiation Risks : Ensure safe handling to minimize radiation exposure to the patient and healthcare providers.

( 5.4 )

5.1Patients with Pulmonary Hypertension Deaths have been reported in patients with severe pulmonary hypertension after the administration of technetium Tc 99m albumin aggregated products [see Adverse Reactions ( 6 )] . Assess patients for history or signs of pulmonary hypertension. PULMOTECH MAA is contraindicated in patients with severe pulmonary hypertension [see Contraindications ( 4 )] .

Administer the lowest number of particles possible, have emergency resuscitation equipment available, and monitor patients for adverse reactions .

5.2Hypersensitivity Reactions Serious hypersensitivity reactions including anaphylaxis have been reported in patients treated with products containing albumin human, including PULMOTECH MAA [see Adverse Reactions ( 6 )] . Obtain a history of allergy or hypersensitivity reactions. PULMOTECH MAA is contraindicated in patients with a history of hypersensitivity to albumin human [see Contraindications ( 4 )] .

Have emergency resuscitation equipment and trained personnel available prior to administration of Technetium Tc 99m Albumin Aggregated Injection. Monitor all patients for hypersensitivity reactions.

5.3Risk of Temporary Impediment to Blood Flow in Patients with Right-to-Left Heart Shunts In patients with right-to-left heart shunts, risk for temporary mechanical impediment to blood flow may exist due to the rapid entry of aggregated albumin into the systemic circulation. Administer the lowest possible number of particles of Technetium Tc 99m Albumin Aggregated Injection in these patients.

5.4Radiation Risks Technetium Tc 99m albumin aggregated contributes to a patient’s overall long-term cumulative radiation exposure. Long-term cumulative radiation exposure is associated with an increased risk for cancer. Ensure safe handling to minimize radiation exposure to the patient and health care providers. Advise patients to hydrate before and after administration and to void frequently after administration [see Dosage and Administration ( 2.2 )] .

🤒 Adverse Reactions ~1 min read ▾

6 ADVERSE REACTIONS The following clinically significant adverse reactions are described elsewhere in labeling: Patients with Pulmonary Hypertension [ see Warnings and Precautions ( 5.1 ) ] . Hypersensitivity Reactions [ see Warnings and Precautions ( 5.2 ) ] . The following adverse reactions associated with the use of technetium Tc 99m albumin aggregated products including PULMOTECH MAA have been identified in clinical studies or postmarketing reports.

Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. Cardiovascular Disorders : Deaths in patients with severe pulmonary hypertension Immune System Disorders : Hypersensitivity reactions such as anaphylaxis, impairment of cardiac and circulatory functions in the form of changes in respiration, pulse, and blood pressure, chest pain, and syncope, urticaria, reddening of the face, sweating, and nausea Skin and Subcutaneous Tissue Disorders : Injection site reactions The following adverse reactions have been reported: Death in patients with severe pulmonary hypertension, anaphylaxis, impairment of cardiac and circulatory functions in the form of changes in respiration, pulse, and blood pressure, chest pain, and possible syncope, urticaria, reddening of the face, sweating, nausea, and injection site reaction.

( 6 ) To report SUSPECTED ADVERSE REACTIONS, contact CURIUM US LLC at 1-866-789-2211 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.

👥 Use in Specific Populations ~2 min read ▾

8 USE IN SPECIFIC POPULATIONS Lactation: Temporarily discontinue breastfeeding. A lactating woman should pump and discard breastmilk for at least 24 hours after technetium Tc 99m albumin aggregated injection administration. ( 8.2 )

8.1Pregnancy Risk Summary Available data from case reports on Technetium Tc 99m Albumin Aggregated Injection use are insufficient to evaluate drug-associated risks of major birth defects, miscarriage, or adverse maternal or fetal outcomes. Animal reproduction studies with technetium Tc 99m albumin aggregated have not been conducted. Although all radiopharmaceuticals have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose, the radiation exposure to the fetus from technetium Tc 99m albumin aggregated is expected to be low (less than 0.50 mGy) (see Data) .

The estimated background risk of major birth defects and miscarriage for the indicated population is unknown. All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2% to 4% and 15% to 20%, respectively.

Data Human Data No adverse fetal effects of radiation risks have been identified for diagnostic procedures involving less than 50 mGy, which represents less than 10 mGy fetal doses.

8.2Lactation Risk Summary Technetium-99m is present in breast milk. There are no data on the effects of technetium Tc 99m albumin aggregated on the breastfed infant or the effects on milk production. PULMOTECH MAA is used for imaging in infants with lung disease; exposure to technetium-99m via breastmilk is expected to be lower.

Based on clinical guidelines, exposure of technetium Tc 99m albumin aggregated to a breastfed infant may be minimized by advising a lactating woman to temporarily discontinue breastfeeding and to pump and discard breast milk for a minimum of at least 24 hours after administration of Technetium Tc 99m Albumin Aggregated Injection. The developmental and health benefits of breastfeeding should be considered along with a mother’s clinical need for PULMOTECH MAA, any potential adverse effects on the breastfed child from technetium Tc 99m albumin aggregated or from the underlying maternal condition.

8.4Pediatric Use PULMOTECH MAA, after radiolabeling with technetium Tc-99m, is indicated for lung scintigraphy as an adjunct in the evaluation of pulmonary perfusion in pediatric patients (birth to less than 17 years of age). The safety profile of Technetium Tc99m Albumin Aggregated Injection is similar to the one in adults. The safety and efficacy of PULMOTECH MAA have not been established for peritoneovenous shunt scintigraphy in pediatric patients.

8.5Geriatric Use No formal studies of PULMOTECH MAA in subjects aged 65 and over were performed to determine whether they respond differently from younger adult subjects. Other reported clinical experience has not identified differences in responses between the elderly and younger adult patients. In general, dose selection for an elderly patient should be cautious; administering the low end of the particle dosing range, reflecting the greater frequency of decreased hepatic, renal, or cardiac function, and of concomitant disease or other drug therapy.

🤰 Pregnancy 182 words ▾

8.1Pregnancy Risk Summary Available data from case reports on Technetium Tc 99m Albumin Aggregated Injection use are insufficient to evaluate drug-associated risks of major birth defects, miscarriage, or adverse maternal or fetal outcomes. Animal reproduction studies with technetium Tc 99m albumin aggregated have not been conducted. Although all radiopharmaceuticals have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose, the radiation exposure to the fetus from technetium Tc 99m albumin aggregated is expected to be low (less than 0.50 mGy) (see Data) .

The estimated background risk of major birth defects and miscarriage for the indicated population is unknown. All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2% to 4% and 15% to 20%, respectively.

Data Human Data No adverse fetal effects of radiation risks have been identified for diagnostic procedures involving less than 50 mGy, which represents less than 10 mGy fetal doses.

🧒 Pediatric Use 69 words ▾

8.4Pediatric Use PULMOTECH MAA, after radiolabeling with technetium Tc-99m, is indicated for lung scintigraphy as an adjunct in the evaluation of pulmonary perfusion in pediatric patients (birth to less than 17 years of age). The safety profile of Technetium Tc99m Albumin Aggregated Injection is similar to the one in adults. The safety and efficacy of PULMOTECH MAA have not been established for peritoneovenous shunt scintigraphy in pediatric patients.

🧓 Geriatric Use 83 words ▾

8.5Geriatric Use No formal studies of PULMOTECH MAA in subjects aged 65 and over were performed to determine whether they respond differently from younger adult subjects. Other reported clinical experience has not identified differences in responses between the elderly and younger adult patients. In general, dose selection for an elderly patient should be cautious; administering the low end of the particle dosing range, reflecting the greater frequency of decreased hepatic, renal, or cardiac function, and of concomitant disease or other drug therapy.

🧬 Clinical Pharmacology ~1 min read ▾

12 CLINICAL PHARMACOLOGY

12.1Mechanism of Action Within 1 to 5 minutes of intravenous injection, over 90 percent of the technetium Tc 99m albumin aggregated particles are trapped in the arterioles and capillaries of the lung. Following intraperitoneal administration, technetium Tc 99m albumin aggregated mixes with the peritoneal fluid. Clearance from the peritoneal cavity varies from insignificant, which may occur with complete shunt blockage, to very rapid clearance with subsequent transfer into the systemic circulation when the shunt is patent.

12.2Pharm a codynamics The exposure-response relationship and time course of pharmacodynamic response for the safety and effectiveness of technetium Tc 99m albumin aggregated have not been fully characterized.

12.3Pharmacokinetics Distribution Organ selectivity is a direct result of particle size. At 10 micrometer and below, the albumin aggregates are taken up by the reticuloendothelial system. Above 10 to 15 micrometer, the aggregates become lodged in the lung capillaries by a purely mechanical process.

Distribution of aggregated albumin in the lungs is a function of regional pulmonary blood flow. The albumin aggregated is sufficiently fragile for the capillary micro-occlusion to be temporary. Erosion and fragmentation reduce the particle size, allowing passage of the aggregates through the pulmonary alveolar capillary bed.

The fragments then accumulate in the reticuloendothelial system. Elimination Elimination of the technetium Tc 99m albumin aggregated particles from the normal and abnormal human lungs occurs with a biological half-life of 10.8 hours (range 6.9 to 19 hours, n=5).

🧬 Mechanism of Action 77 words ▾

12.1Mechanism of Action Within 1 to 5 minutes of intravenous injection, over 90 percent of the technetium Tc 99m albumin aggregated particles are trapped in the arterioles and capillaries of the lung. Following intraperitoneal administration, technetium Tc 99m albumin aggregated mixes with the peritoneal fluid. Clearance from the peritoneal cavity varies from insignificant, which may occur with complete shunt blockage, to very rapid clearance with subsequent transfer into the systemic circulation when the shunt is patent.

📦 How Supplied / Storage and Handling ~1 min read ▾

16 HOW SUPPLIED/STORAGE AND HANDLING How Supplied PULMOTECH MAA (kit for the preparation of technetium Tc 99m albumin aggregated) injection contains 2 mg of albumin aggregated as a white lyophilized powder in a multiple-dose reaction vial, sealed under an atmosphere of nitrogen, for radiolabeling with Sodium Pertechnetate Tc 99m Injection to prepare Technetium Tc 99m Albumin Aggregated Injection. PULMOTECH MAA is supplied as: a carton (clam shell) of 5 vials (NDC 69945-139-20) a carton of 30 vials (NDC 69945-139-40) Each 5-vial carton contains 5 multiple-dose reaction vials and 5 radioassay information labels.

Each 30-vial carton contains 30 multiple-dose reaction vials and 30 radioassay information labels. Storage and Handling Before radiolabeling, store supplied reaction vials at 2°C to 25°C (36°F to 77ºF). After radiolabeling with Sodium Pertechnetate Tc 99m Injection, store Technetium Tc 99m Albumin Aggregated Injection in a lead vial shield with cap in place, refrigerated at 2°C to 8°C (36°F to 46ºF) when not in use.

Use within 18 hours after radiolabeling [ see Dosage and Administration ( 2.5 )] . Dispose unused Technetium Tc 99m Albumin Aggregated Injection in compliance with the appropriate regulations of the government agency authorized to license the use of this radionuclide. This preparation is approved for use by persons under license by the Nuclear Regulatory Commission or the relevant regulatory authority of an Agreement State.

📋 Description ~2 min read ▾

11 DESCRIPTION

11.1Product Characteristics PULMOTECH MAA contains albumin aggregated obtained by fractionating material (source blood, plasma, serum, or placentas) from healthy human donors. The macroaggregated albumin (MAA) particles are formed by heat denaturation of stannous chloride treated albumin human under controlled conditions. Each vial contains 2,000,000 to 4,000,000 particles.

The particle size distribution of the aggregated albumin is such that not less than 90% are 10 to 90 micrometers in size. There are no aggregated albumin particles greater than 150 micrometers in size as determined by circular equivalents. PULMOTECH MAA (kit for the preparation of technetium Tc 99m albumin aggregated) injection provides a sterile, non-pyrogenic, non-radioactive, white lyophilized powder in a multiple-dose reaction vial, sealed under an atmosphere of nitrogen, for radiolabeling with Sodium Pertechnetate Tc 99m Injection to prepare Technetium Tc 99m Albumin Aggregated Injection, a radioactive diagnostic agent, for intravenous or intraperitoneal use.

Each reaction vial contains 2 mg of albumin aggregated, albumin human (7.1 mg), stannous chloride (0.1 mg minimum; 0.22 mg maximum stannous and stannic), sodium chloride (9 mg). Hydrochloric acid may have been added for pH adjustment. The pH is between 5 and 7.

It contains no preservatives.

11.2Physical Characteristics Technetium-99m decays by isomeric transition with a physical half-life of 6.02 hours. The principal photon that is useful for detection and imaging is listed in Table 4. Table 4 – Principal Radiation Emission Data for Technetium-99m Radiation Mean % per Disintegration Energy (keV) Gamma-2 89.07 140.5

11.3 External Radiation The specific gamma ray constant for technetium-99m is

0.78R/mCi-hr at 1 cm. The first half-value thickness of lead (Pb) for technetium-99m is 0.017 cm. A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 5.

For example, the use of 0.25 cm of Pb will decrease the external radiation exposure by a factor of about 1,000. Table 5 – Radiation Attenuation by Lead Shielding Shield Thickness(Pb) cm Coefficient of Attenuation 0.017 0.5 0.08 10 -1 0.16 10 -2 0.25 10 -3 0.33 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected time intervals after the time of calibration are shown in Table 6. Table 6– Physical Decay Chart for Technetium-99m, Half-Life

6.02Hours Hours Fraction Remaining Hours Fraction Remaining 0* 1.000 7 0.447 1 0.891 8 0.398 2 0.794 9 0.355 3 0.708 10 0.316 4 0.631 11 0.282 5 0.562 12 0.251 6 0.501 *Calibration Time

💬 Information for Patients 177 words ▾

17 PATIENT COUNSELING INFORMATION Adequate Hydration Advise patients to drink a sufficient amount of water to ensure adequate hydration before their study and urge them to drink and urinate as often as possible during the first hours following the administration of Technetium Tc 99m Albumin Aggregated Injection in order to reduce radiation exposure [see Dosage and Administration ( 2.2 )] . Pregnancy Advise pregnant women of the risk of fetal exposure to radiation doses if they undergo a radionucleotide procedure [see Use in Specific Populations ( 8.1 )].

Lactation Advise a lactating woman to temporally discontinue breastfeeding and to pump and discard breast milk for 24 hours after Technetium Tc 99m Albumin Aggregated Injection administration to minimize radiation exposure to a breastfed infant [see Use in Specific Populations ( 8.2 )]. Manufactured by: CIS bio International Route Departementale 306 Gif-sur-Yvette, Ile-de-France 91190, France U.S License No. 2204 Distributed by: Curium US LLC 2703 Wagner Place Maryland Heights, MO 63043 ©2025 Curium US LLC.

Pulmotech™, Curium™, and the Curium logo are trademarks of a Curium company. A139I0 Curium™

🧬 Pharmacokinetics 130 words ▾

12.3Pharmacokinetics Distribution Organ selectivity is a direct result of particle size. At 10 micrometer and below, the albumin aggregates are taken up by the reticuloendothelial system. Above 10 to 15 micrometer, the aggregates become lodged in the lung capillaries by a purely mechanical process.

Distribution of aggregated albumin in the lungs is a function of regional pulmonary blood flow. The albumin aggregated is sufficiently fragile for the capillary micro-occlusion to be temporary. Erosion and fragmentation reduce the particle size, allowing passage of the aggregates through the pulmonary alveolar capillary bed.

The fragments then accumulate in the reticuloendothelial system. Elimination Elimination of the technetium Tc 99m albumin aggregated particles from the normal and abnormal human lungs occurs with a biological half-life of 10.8 hours (range 6.9 to 19 hours, n=5).

🧬 Pharmacodynamics 29 words ▾

12.2Pharm a codynamics The exposure-response relationship and time course of pharmacodynamic response for the safety and effectiveness of technetium Tc 99m albumin aggregated have not been fully characterized.

🧪 Nonclinical Toxicology 36 words ▾

1 3 NONCLINICAL TOXICOLOGY

13.1Carcinogenesis, Mutagenesis, Impairment of Fertility No long-term animal studies have been performed to evaluate carcinogenic or mutagenic potential or whether technetium Tc 99m albumin aggregated affects fertility in males or females.

📄 Carcinogenesis, Mutagenesis, Impairment of Fertility 32 words ▾

13.1Carcinogenesis, Mutagenesis, Impairment of Fertility No long-term animal studies have been performed to evaluate carcinogenic or mutagenic potential or whether technetium Tc 99m albumin aggregated affects fertility in males or females.

📄 Recent Major Changes 13 words ▾

Dosage and Administration, Directions for Drug Preparation and Handling ( 2.5 ) 10/2025

📄 Package Label / Principal Display Panel ~1 min read ▾

PRINCIPAL DISPLAY PANEL Kit for the Preparation of Technetium Tc 99m Albumin Aggregated NDC 69945-139-10 Pulmotech™ MAA Sterile, Multiple-Dose Vial Rx only Injection For Intravenous or Intraperitoneal use after radiolabeling with Sodium Pertechnetate Tc 99m Injection. Each reaction vial contains 2 mg of albumin aggregated. STORAGE: Before radiolabeling , store at 2°C to 25°C (36°F to 77°F).

After radiolabeling , store vial in a suitable lead shield in a refrigerator at 2°C to 8°C (36°F to 46°F). Use within 18 hours after radiolabeling. Recommended Dosage: See prescribing information.

Manufactured by: CIS bio International, Gif-sur-Yvette Ile-de-France 91190, France U.S. License No. 2204 Distributed by: Curium US LLC, Maryland Heights, MO 63043 A139V0 R08/2023 image description

PRINCIPAL DISPLAY PANEL NDC 69945-139-40 Kit for the Preparation of Technetium Tc 99m Albumin Aggregated Pulmotech™ MAA Injection For Intravenous or Intraperitoneal use after radiolabeling with Sodium Pertechnetate Tc 99m Injection. Rx only STORAGE: Before radiolabeling, store at 2°C to 25°C (36°F to 77°F). After radiolabeling, store vial in a suitable lead shield in a refrigerator at 2°C to 8°C (36°F to 46°F).

Use within 18 hours after radiolabeling. CURIUM™ 30 Multiple-Dose Vials PINCH AT CORNERS / PULL OUT Recommended Dosage: See prescribing information. CARTON CONTAINS: 30 sterile, multiple-dose reaction vials 30 radioassay information labels 1 Prescribing Information Each reaction vial contains 2 mg of albumin aggregated, albumin human (7.1 mg), stannous chloride (0.1 mg minimum; 0.22 mg maximum stannous and stannic), and sodium chloride (9 mg).

Hydrochloric acid has been used for pH adjustment; Sealed under nitrogen; Contains no preservative. Manufactured by: CIS bio International Route Departementale 306 Gif-sur-Yvette Ile-de-France 91190, France U.S. License No.

2204 Distributed by: Curium US LLC 2703 Wagner Place Maryland Heights, MO 63043 Convenient Reorder Point Maximum Six Vials Remaining Open Flap For Prescribing Information and Radioassay Information Labels A139DK R08/2023 image description

Source: FDA Structured Product Labeling, mirrored from DailyMed / openFDA. Prefer the government’s original formatting? View this label on DailyMed ↗

Medicaid utilization & spend

📍 This exact package only: Medicaid data is reported per full 11-digit NDC — labeler, product and pack size — so every number here is for this package alone, not the drug overall. Other pack sizes report separately.
💊 Pharmacy benefit only: These are Medicaid outpatient pharmacy claims, billed by NDC. They exclude the medical benefit — clinic- or hospital-administered drugs billed under HCPCS J-codes — so drugs used mostly that way (e.g. Avastin, Lucentis, Keytruda) can look low or missing here. That’s expected, not an error.
📅 Q4 2025 – Q1 2026 · 2 quarters of data
ⓘ The newest quarter is usually incomplete when first published; states restate recent quarters in later CMS releases, so the latest figures typically revise upward. State coverage-policy changes can also shift quarter-to-quarter totals.
Prescriptions last 4 qtrs
29
Units reimbursed last 4 qtrs
29
Gross reimbursed last 4 qtrs
$218.06
Avg / prescription
$7.52
Avg / unit
$7.5193
Latest quarter Q1 2026
11Rx
Fee-for-service vs managed care ⓘ
100% MCO
Fee-for-service · 0 Rx Managed care · 29 Rx
State Medicaid map
Alaska: no data reported AK Maine: no data reported ME Washington: no data reported WA Idaho: no data reported ID Montana: no data reported MT North Dakota: no data reported ND Minnesota: no data reported MN Wisconsin: no data reported WI Michigan: no data reported MI New York: no data reported NY Vermont: no data reported VT New Hampshire: no data reported NH Oregon: no data reported OR Nevada: no data reported NV Wyoming: no data reported WY South Dakota: no data reported SD Iowa: no data reported IA Illinois: no data reported IL Indiana: no data reported IN Ohio: no data reported OH Pennsylvania: no data reported PA New Jersey: no data reported NJ Massachusetts: 29 units · 0.4 per 100k residents MA California: no data reported CA Utah: no data reported UT Colorado: no data reported CO Nebraska: no data reported NE Missouri: no data reported MO Kentucky: no data reported KY West Virginia: no data reported WV Virginia: no data reported VA Maryland: no data reported MD Connecticut: no data reported CT Rhode Island: no data reported RI Arizona: no data reported AZ New Mexico: no data reported NM Kansas: no data reported KS Arkansas: no data reported AR Tennessee: no data reported TN North Carolina: no data reported NC South Carolina: no data reported SC Delaware: no data reported DE Oklahoma: no data reported OK Louisiana: no data reported LA Mississippi: no data reported MS Alabama: no data reported AL Georgia: no data reported GA D.C.: no data reported DC Hawaii: no data reported HI Texas: no data reported TX Florida: no data reported FL
Units reimbursed · per 100k residents
0.40.4
gray = no data reported ⓘ
Colors are per 100,000 residents, so big states don’t automatically dominate. Tap or hover a state for its actual totals.
Tap or hover a state
…for its Medicaid breakdown
🏆 Top states by units · per 100k residents
1 Massachusetts 0.4 /100k
National units — by quarter
💵 About the dollar figures: “reimbursed” is what Medicaid paid pharmacies before confidential manufacturer rebates, so the program’s real net cost is lower than these numbers. Fee-for-service and managed-care claims are combined unless split above. Source: CMS State Drug Utilization Data; per-100k rates use 2023 Census population estimates.

Medicaid utilization by pack size

Medicaid (SDUD) totals over the four most recent reported quarters for every package size of this drug — handy when a specific package (e.g. a starter/titration pack) carries little or no Medicaid volume on its own.
5 vials69945-0139-20 No Medicaid data
Drug total (last 4 qtrs): 29 Rx · 29 units · $218 gross reimbursed
Tap a pack size to open its page. Source: CMS State Drug Utilization Data, last 4 quarters.

Reported adverse events (FAERS)

Read carefully: FAERS reports are voluntary and unverified. Counts are not incidence, do not establish causation, are subject to reporting bias, and cannot be used to compare one drug to another. Shown for signal context only. Reports for Pulmotech MAA (this brand).

Top reported reactions

Dizziness1
Muscular Weakness1
Product Preparation Error1
Radioisotope Scan Abnormal1
Syncope1
Ventilation/perfusion Scan Abnormal1

Reporter sex

3 reports
Male · 33%
Female · 67%
Reports over time (by year) — tap or hover for the count & year
2021 2022 2024 2026 2 0
Most recent year is provisional (FAERS lags ~3 months).
Where does this data come from?
Adverse-event reports from the FDA Adverse Event Reporting System (FAERS) via openFDA. FAERS reports are voluntary and unverified — counts are not incidence and don’t establish causation.

About this NDC listing & data coverage

Finished prescription product
What data is (and isn’t) available for this NDC — tap to expand
NDC identity (package / product / labeler codes) ✓ Available
Labeler ✓ Available
Product & package description ✓ Available
Marketing category & status ✓ Available
Active ingredient / dosage form / route ✓ Available
FDA label (SPL via DailyMed) ✓ Available
Package photos — Not published for this NDC No photo available yet for this listing.
Inactive ingredients (structured) ✓ Available
NADAC pharmacy acquisition price (CMS) — Not published for this NDC CMS publishes NADAC only for NDCs reported in its retail-pharmacy survey.
Orange Book / therapeutic-equivalence data ✓ Available
HCPCS J-code billing crosswalk — Not published for this NDC Most self-administered / retail products have no J-code — that is normal.
Medicaid utilization (CMS SDUD) ✓ Available
“Not published” reflects what the public FDA / CMS / NLM sources provide for this exact package code — it is a property of the data feeds, not a judgment about the product.

Questions about this listing

Why is there no price listed?
The pricing shown on our NDC pages comes from CMS NADAC, a voluntary survey of retail community pharmacy invoices. CMS does not publish a NADAC for every NDC — packages outside the retail survey (institutional and hospital products, bulk packages, discontinued items, and many OTC items) may never receive one. A missing price reflects the survey's scope, not this product's actual cost, and does not mean the product is free or unavailable.
Is the NDC printed on the package the same as the 11-digit billing NDC?
Yes, they identify this exact package in different formats. The form printed on the packaging and shown on DailyMed is the one the FDA registered. Insurance claims use a fixed 11-digit 5-4-2 format, so the short segment is padded with a leading zero and the dashes are dropped. The Identity section at the top of this page lists each form of this code.
Is this package still being marketed?
Yes, per the latest FDA NDC Directory data on this page: this package is listed as actively marketed, with no marketing end date reported by Curium US LLC. Listing status can change — the directory data on this page refreshes weekly.
Does this product come in other package sizes?
Yes — the FDA directory lists 1 other package presentation of this same product, including 5 vials (69945-0139-20). Each has its own NDC and its own page — see the package list near the top of this page.
Who lists this product with the FDA?
Curium US LLC is the labeler of record for this NDC — the company under whose FDA-assigned code the package is listed. The labeler may be the manufacturer itself or a distributor marketing the product under its own code.
Do I need a prescription for this product?
This NDC is listed with FDA as a prescription product, so it is dispensed under a prescriber's order. Your pharmacist can tell you whether any over-the-counter forms of the same medication exist.
This page identifies an FDA-listed package (the NDC) and reports public regulatory and pricing data about the listing. It is reference information, not a medical recommendation — talk to your pharmacist or prescriber about your own medication.
Where does this data come from?
Listing facts (marketing category, packager status, marketing dates) from the FDA openFDA NDC Directory; label availability from DailyMed; pricing coverage from CMS NADAC; equivalence scope from the FDA Orange Book.
For educational and professional reference only — not medical advice. Pricing reflects published NADAC and CMS ASP (free public data) and may differ from your acquisition cost; always verify before billing or dispensing.